GAS CONNECTIONS

NOTE: The Aquastar 125 B is supplied with a gas pressure regulator that must be installed on the heater before attaching the gas supply line. See fig. 5. Failure to install the gas regulator as shown in figure 5 will be a violation of CSA certification of the unit. The regulator supplied with the heater is preset for the gas shown on the rating plate to the correct pressure. It is an appliance level regulator designed for (low inlet) pressure (less than 1/ 2 Psig or 15” W.C.)

DO NOT connect to an unregulated or high pressure propane line or to a high pressure commercial natural gas line.

GAS LINE SIZING

-It is strongly recommended that the Natural Gas pipe be Black Iron pipe the entire distance from the outside meter to the inlet of the Aquastar regulator. 1/2” Black Iron pipe up to 10 feet, 3/4” Black Iron pipe up to 40 feet and 1” Black Iron pipe up to 150 feet distances. Flex line tubing is NOT recommended, but if used then oversize it.

-It is strongly recommended that the LP Gas pipe be semi-rigid copper or Black Iron pipe from the outside regulator to the inlet of the Aquastar regulator. For semi- rigid copper piping: 5/8” up to 20 feet and 3/4” up to 60 feet distances. For Black Iron piping: 1/2 “ up to 45 feet and 3/4” up to 160 feet distances. Flex line tubing is NOT recommended, but if used then oversize it.

THESE FIGURES ARE FOR AQUASTAR SUPPLY ONLY, ALL OTHER APPLIANCES IN THE BUILDING WILL NEED TO BE INCLUDED IN THE PIPE SIZING.

GAS INLET PIPE

PRESSURE TAP

PLASTIC VENT CAP

PRESSURE REGULATOR (with directional arrow on reverse side pointing upward)

Fig. 5 - Installation of Gas Pressure Regulator

The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure (as indicated on the rating plate and in the manual for altitude up to 2000 feet (660 meters) above sea level. On appliances being installed above 2000 ft (660 meters) elevation, the inlet gas pressure should be set at installation to the value shown below.

NOTE: The gas pressures specified below refer to pressures taken at the pressure tap on the gas inlet pipe just above the regulator (See Fig. 5).

These readings should be taken while the heater is operating at full input — i.e. maximum water flow with the temperature dial selector turned all the way clockwise.

MAXIMUM INLET GAS FLOW PRESSURE SETTING

Altitude

Natural Gas

Liquid Propane

 

inches W.C:

inches W.C:

0' - 2.000 ft

5.7"

10.5"

2.000 ft - 4.500 ft

4.6"

8.4"

Above 4.500 ft consult your local gas supplier.

National Fuel Gas Code requires that a sediment trap (drip leg) be installed on gas appliances not so equipped. The drip leg must be accessible and not subject to freezing conditions. Install in accordance with the recommendations of the serving gas supplier.

WARNING: The heater must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 0.5 psig.

The water heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or more than 0.5 psig.

The water heater, including the pressure regulator provided with it, must not be operated at gas supply pressures in excess of 0.5 psig. If overpressure has occurred, such as through improper testing of the gas lines or malfunction of the supply system, the gas valve and regulator must be checked for safe operation. Make sure that the regulator vent is protected against blockage.

When your connections are made, check for gas leaks at all joints (not just the ones you made). Apply some soapy water to all gas fittings and gas valve. Soap bubbles are a sign of a leak.

NOTE: Do not apply soap solution to pilot filter screen or pilot orifice area. If you have a leak, shut off the gas. After verifying that required gaskets are in place, tighten appropriate fittings to stop leak. Turn the gas on and check again with a soapy solution. Never test for gas leaks using a match or flame.

10

6 720 607 030

Page 10
Image 10
Bosch Appliances 125B NG, 125B LP specifications GAS Connections, GAS Line Sizing, Maximum Inlet GAS Flow Pressure Setting

125B NG, 125B LP specifications

Bosch Appliances has long been a trusted name in kitchen technology, and their 125B LP and 125B NG models are no exception. These gas appliances combine advanced features with top-notch engineering, ensuring excellent performance and reliability in the kitchen. Designed for both professionals and home cooks, the 125B series caters to diverse culinary needs.

One of the main features of the Bosch 125B model is its dual fuel capability. The LP (liquefied petroleum) and NG (natural gas) options make it flexible for various installations and preferences. This versatility ensures that users can easily find the right setup for their kitchens, whether they're using propane or natural gas.

The burners in the 125B series are designed with precision in mind. Each model features high-efficiency burners that deliver a maximum output of 15,000 BTUs. This level of power enables rapid heating for boiling, frying, or searing, while the low-simmer setting allows for gentle cooking tasks such as sauces and delicate soups. The continuous cast iron grates offer both durability and stability, allowing for easy movement of pots and pans across the cooking surface.

An additional technological highlight of the Bosch 125B series is the flame failure safety device. This essential safety feature automatically cuts off the gas supply if the flame goes out, providing peace of mind for users. The inclusion of electronic ignition also enhances convenience, making it easy to start the burners with just a turn of the knob.

The sleek design of the Bosch 125B appliances blends seamlessly into any kitchen decor. With a professional stainless steel finish, they add an element of sophistication while being easy to clean and maintain. The intuitive control knobs are ergonomically designed, ensuring smooth and precise adjustments to the flame.

In terms of installation, both the 125B LP and NG models are designed for straightforward setup, making them suitable for renovation projects or new builds. Bosch Appliances also offers a range of accessories to further enhance the functionality and aesthetic of the kitchen setup.

Overall, the Bosch 125B LP and 125B NG appliances represent a perfect combination of efficiency, safety, and style. With their robust features and advanced technology, they promise to elevate the cooking experience for anyone who values quality and performance in the kitchen. Whether you're a novice home cook or a seasoned chef, these models are sure to meet and exceed your culinary expectations.