Bosch Appliances 24I RSF manual White & Brown, Aps Ok

Models: 24I RSF

1 36
Download 36 pages 30.62 Kb
Page 32
Image 32

LAir Pressure Switch Check

Remove BROWN and

WHITE terminals from air pressure switch

With no demand, is a short-circuit observed NO

at exposed APS

terminals?

Air pressure switch

faulty

YES

Reconnect the

WHITE & BROWN

wire and remove the GREEN wire. Initiate

ademand. Does the fan run?

YES

With fan running

disconnect BROWN wire. (DO NOT touch chassis with it). Is a short circuit observed across exposed APS

terminals?

NO

Is there mains 230V

NO

 

at fan connector X4

PCB faulty

 

 

 

pins 1 and 3?

 

 

YES

 

 

Fan or fan cable

 

 

faulty

 

NO

Air pressure switch

 

 

faulty

 

YES

APS OK

Gas Valve Check

Is gas pressure present

NO

Ensure gas supply

at input to gas valve?

 

 

 

YES

 

 

Is live output present at

NO

Faulty board

X5 pins 1 & 2 relative to

 

Replace

neutral at pin 3?

 

 

 

YES

Is gas pressure present NO at input to burner?

YES

Gas valve OK

Faulty gas valve

Replace

32

Page 32
Image 32
Bosch Appliances 24I RSF manual White & Brown, Aps Ok