Bosch Appliances 250 SXO LP Water connections, Plumbing Connections and Pressure Relief, Valve

Models: 250 SXO LP 250 SXO NG

1 31
Download 31 pages 38.24 Kb
Page 13
Image 13
2.10 Water connections

Appliance details

2.10 Water connections Fig. 16 Plumbing Connections and Pressure Relief

When facing the heater, the ¾” cold water inlet is on the bottom right and the hot water outlet is on the bottom left. Install the heater where it’s centrally close to hot water use points if possible, and make hot water piping runs as short as possible.

ValveManual backgroundManual backgroundManual background INLET FILTER

Manual background SCREEN

lowest pressure range setting recommended is 30-50 psi (2.07 and 3.45bar).

Connecting the pressure relief valve (PRV)

A listed pressure relief valve supplied with the heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater. No reducing coupling or other restriction may be installed in the discharge line. The discharge line must be a minimum of 4” above a drain and installed such that it allows complete drainage of both the PRV and the line. The location of the PRV must be readily accessible for servicing or replacement, and be mounted as close to the water heater as possible. See Fig. 16. To install the PRV, a suitable fitting connected to an extension on a “T” fitting can be sweated to the hot water line.

Support all piping.

COLD

HOT Manual background

Fig. 15

B THE USE OF A UNION WHEN CONNECTING

BOTH WATER PIPES TO THE INLET AND

OUTLET CONNECTIONS IS RECOMMENDED,

THIS WILL FACILITATE ANY NECESSARY

SERVICING AND REQUIRED CLEANING OF

THE INLET WATER PARTICLE SCREEN.

Although water piping throughout your structure may be

 

other than copper, we recommend that copper piping

Fig. 16 Plumbing Connections and Pressure Relief

or suitably rated stainless steel flex line piping be used

Valve

for at least three feet before and after the heater (follow

 

local codes if more stringent). Never sweat any rigid

 

piping directly to or beneath the water connections,

 

damage can occur to the internal water valve from

 

heating of the pipe. Plastics or other PEX type plumbing

 

line materials are not suitable for connecting directly to

 

the water heater. Keep water inlet and outlet pipes to no

 

less than ¾" (19.05mm) diameter to allow the full flow

 

capacity.

 

It is recommended that all water piping below the

 

heater be properly insulated to avoid heat loss. If

 

below freezing temperatures are ever anticipated

 

where the heater is located, insulation material

 

is required and must be capable of protecting the

 

piping from freezing. The freeze protection that is

 

equipped within the heater will not prevent any

 

freeze damage to the exterior water piping.

 

If the cold and hot connections to the heater are

 

reversed, the heater will not function. Be certain there

 

are no loose particles or dirt in the piping. Blow out or

 

flush the lines before connecting to the water heater.

 

Full port valves should be installed on both the cold

 

water supply and hot water outlet lines to facilitate

 

servicing the heater (see Fig. 16). For installation on a

 

private well system with the use of a pressure tank, the

 

6 720 607 440

13

Page 13
Image 13
Bosch Appliances 250 SXO LP, 250 SXO NG manual Water connections, Plumbing Connections and Pressure Relief, Valve