Characteristic Data
Pilot orifice diameter (mm) | NG | 0.30 |
| LPG | 0.19 |
| TG | 0.56 |
| TLP | 0.56 |
Burner injector diameter (mm) | NG | 1.20 |
| LPG | 0.75 |
| TG | 2.15 |
| TLP | 2.15 |
Burner pressure ( kPa ) | NG | 0.87 |
| LPG | 2.60 |
| TG | 0.40 |
| TLP | 0.40 |
Water flow selector at left hand stop. |
|
|
Maximum water flow | 10 litres / minute | |
Temperature rise | 25°C |
|
Minimum inlet pressure | NG | 90 kPa |
|
| ( 9.0 metres W.G.) |
| LP | 55 kPa |
|
| ( 5.5 metres W.G.) |
Water flow selector at right hand stop |
|
|
Minimum water flow | 4.5 litres / minute | |
Temperature rise | 55°C |
|
Minimum inlet pressure | NG | 30 kPa |
|
| ( 3 metres W.G. ) |
| LP | 10 kPa |
|
| ( 1 metre W.G. ) |
Refer to rating label located on the bottom right hand corner of the back panel for additional data.
Freezing Weather
In areas where the atmospheric temperature may drop below 0°C, the heater must be drained to prevent damage by expansion of freezing water. For appliances installed in locations where the temperature falls below 0°C for brief periods , the installation of an EXOGEL expansion valve, (part number H 707 060 151), will minimise the possibility of damage to the appliance.
This water heater MUST NOT be installed in areas where the temperature remains below 0°C for extended periods.
Hot Water
1 Metre minimum
Exogel
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas that for which it was originally manufactured, please contact your local gas authority, authorised service agent or the manufacturer