Bosch Appliances 600 Characteristic Data, Conversion and Spare Parts, Freezing Weather

Models: 600

1 7
Download 7 pages 8.51 Kb
Page 3
Image 3
Characteristic Data

Characteristic Data

Pilot orifice diameter (mm)

NG

0.30

 

LPG

0.19

 

TG

0.56

 

TLP

0.56

Burner injector diameter (mm)

NG

1.20

 

LPG

0.75

 

TG

2.15

 

TLP

2.15

Burner pressure ( kPa )

NG

0.87

 

LPG

2.60

 

TG

0.40

 

TLP

0.40

Water flow selector at left hand stop.

 

 

Maximum water flow

10 litres / minute

Temperature rise

25°C

 

Minimum inlet pressure

NG

90 kPa

 

 

( 9.0 metres W.G.)

 

LP

55 kPa

 

 

( 5.5 metres W.G.)

Water flow selector at right hand stop

 

 

Minimum water flow

4.5 litres / minute

Temperature rise

55°C

 

Minimum inlet pressure

NG

30 kPa

 

 

( 3 metres W.G. )

 

LP

10 kPa

 

 

( 1 metre W.G. )

Refer to rating label located on the bottom right hand corner of the back panel for additional data.

Freezing Weather

In areas where the atmospheric temperature may drop below 0°C, the heater must be drained to prevent damage by expansion of freezing water. For appliances installed in locations where the temperature falls below 0°C for brief periods , the installation of an EXOGEL expansion valve, (part number H 707 060 151), will minimise the possibility of damage to the appliance.

This water heater MUST NOT be installed in areas where the temperature remains below 0°C for extended periods.

Hot Water

1 Metre minimum

Freezing WeatherConversion and Spare PartsManual background Exogel

Conversion and Spare Parts

For spare parts or conversion of the heater to operate on a different gas that for which it was originally manufactured, please contact your local gas authority, authorised service agent or the manufacturer

BISN0047.0

26/06/2007 Page 3

Page 3
Image 3
Bosch Appliances 600 operating instructions Characteristic Data, Conversion and Spare Parts, Freezing Weather