1.4.2 Characteristics

1.4.2 Characteristics

1.4.2 Characteristics

Terminal Equipment Loop Limit

Minimum Leakage Resistance

Maximum Number of Extension Instruments per Line

Ring Voltage

Trunk Loop Limit

Hookswitch Flash/Recall Timing Range

BRI Cards Internal ISDN Mode

Door Opener Current Limit

External Relay Current Limit

External Sensor Current Limit

Paging Terminal Impedance

MOH (Music on Hold) Terminal Impedance

PT: KX-DT300/KX-T7600 series DPT: 90 Ω; all other DPTs/APTs: 40 Ω

SLT: 600 Ω including set

Doorphone: 20 Ω

CS: 130 Ω; PT-interface CS: 65 Ω

15 000 Ω minimum

1.for PT or SLT

2.by Parallel or eXtra Device Port connection of an APT/DPT and an

SLT

3.by Digital eXtra Device Port connection of 2 DPTs and an SLT

75 Vrms at 20 Hz/25 Hz depending on the Ringing Load

1600 Ω maximum

24 ms to 2032 ms

Supply Voltage: 40 V

Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines

Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines

Power Supply Method: Phantom Power Supply

24 V DC/30 V AC, 1 A maximum

24 V DC/30 V AC, 1 A maximum

Power to the external sensor is provided from the EIO4 card and must be grounded through the EIO4 card. For the connection diagram, refer to "2.6.4 EIO4 Card (KX-TDA0164)".The PBX detects input from the sensor when the signal is under 100 Ω.

600Ω

10 000 Ω