Panasonic KX-TDA100 Connection of 2.4 GHz Portable Stations, Overview, Connection Card, Equipment

Models: KX-TDA100

1 282
Download 282 pages 61.74 Kb
Page 182
Image 182
2.9 Connection of 2.4 GHz Portable Stations

2.9.1 Overview

2.9 Connection of 2.4 GHz Portable Stations

2.9.1 Overview

Required Equipment and Maximum Number of Calls

CSs determine the area covered by the wireless system. The number of calls that can be made simultaneously through each CS varies depending on the model, as follows:

CS

KX-TDA0151

KX-TDA0152

KX-TDA0141

KX-TDA0142

Note

Connection Card

DHLC/DLC

CSIF

DHLC/DLC

CSIF

Maximum Calls

2

3

2

3

Compatible PSs

KX-TD7684

KX-TD7694

KX-TD7680

KX-TD7690

For more details about the PS, refer to the Operating Instructions of the PS.

Required Distances between Equipment

CAUTION

Keeping some distance between the equipment listed below may prevent interference. (The distance may vary depending on the environment.)

Equipment

CS and office equipment such as a computer, telex, fax machine, etc.

CS and PS

Each PS

PBX and CS

CS and CS

Distance

More than 2 m

More than 1 m

More than 0.5 m

More than 2 m

More than 15 m*1

*1

KX-TDA0151CN: More than 3 m

 

The CS should be kept free of dust, moisture, high temperature (more than 40 °C), low temperature (less than 0 °C), and vibration, and should not be exposed to direct sunlight.

The CS should not be placed outdoors (use indoors).

The CS should not be placed near high-voltage equipment.

The CS should not be placed on a metal object.

Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere with the KX-TDA/ KX-TDE wireless system. Examples of such systems are cordless telephones, wireless LAN, Home RF, microwave ovens and other ISM devices. These systems may cause minor noise.

Notice

Please take into consideration the distance between the CSs when site planning. Please consult a certified dealer for details.