Panasonic KX-TDA100 Switch Settings, Pin Assignments, RJ45 Connector for Trunk Use, Type, Level

Models: KX-TDA100

1 282
Download 282 pages 61.74 Kb
Page 97
Image 97
Manual background

2.4.9 PRI30 Card (KX-TDA0290CE/KX-TDA0290CJ)

Switch Settings

Switch

Termination

A/B

Type

Slide

Slide

Usage and Status Definition

Select 120 Ω (default) or 75 Ω to match the connector type to be used.

When using an RJ45 connector, select A (default) for trunk or B for extension use.

When using BNC connectors, make sure that A is selected.

Pin Assignments

RJ45 Connector for Trunk Use

Manual backgroundManual background 8

1

No.

1

2

3

4

5

6-8

Signal Name

RX+

RX-

Reserved

TX-

TX+

Reserved

Level [V]

(+)

(-)

(-)

(+)

Function

Receive data (+)

Receive data (-)

Transmit data (-)

Transmit data (+)

RJ45 Connector for Extension Use

Manual backgroundManual background 8

1

No.

1

2

3

4

5

6-8

Signal Name

TX-

TX+

Reserved

RX+

RX-

Reserved

Level [V]

(-)

(+)

(+)

(-)

Function

Transmit data (-)

Transmit data (+)

Receive data (+)

Receive data (-)

BNC (coaxial) Connector (TX)

 

No.

Signal Name

Level [V]

Function

1

1

TX+

(+)

Transmit data (+)

2

2

TX-

(-)

Transmit data (-)

 

BNC (coaxial) Connector (RX)

 

No.

Signal Name

Level [V]

Function

1

1

RX-

(-)

Receive data (-)

2

2

RX+

(+)

Receive data (+)

 

Installation Manual