Panasonic KX-TDA100 Power Supply Unit Selection, Load Figure Calculation, PSU Capacity, PSU Type

Models: KX-TDA100

1 282
Download 282 pages 61.74 Kb
Page 37
Image 37
Power Supply Unit Selection

1.4.3 System Capacity

Power Supply Unit Selection

The PBX needs a power supply unit (PSU) suitable for its configuration. Calculate the load figure from the type and number of items of equipment to be connected, and determine the type of PSU that will be required.

Load Figure Calculation

 

Equipment Type

 

Load Figure

 

 

 

 

 

 

PT

KX-DT300 series DPT/KX-DT300 series DSS

 

1

 

 

console/KX-T7600 series DPT/KX-T7600 series

 

 

 

 

DSS console

 

 

 

 

 

 

 

 

 

KX-T7560/KX-T7565 DPT

 

1

 

 

 

 

 

 

 

Other DPT/Other DSS console

 

4

 

 

 

 

 

 

 

APT

 

4

 

 

 

 

 

 

 

IP-PT

 

0

 

 

 

 

 

 

Extension Card*1

DHLC8

 

8

 

 

 

 

 

 

 

SLC8

 

8

 

 

 

 

 

 

 

SLC16

 

16

 

 

 

 

 

 

 

CSLC16

 

16

 

 

 

 

 

 

 

MSLC16

 

16

 

 

 

 

 

 

CS (1 unit)

 

 

4

 

 

 

 

 

 

PT-interface CS (1 unit)

 

 

4

 

 

 

 

 

 

PT-interface CS (High-density) (1 unit)

 

8

 

 

 

 

 

 

ISDN Extension

 

 

2

 

 

 

 

 

 

VPS (1 port)

 

 

1

 

 

 

 

 

 

*1

Only the extension cards that can support SLTs count for the load figures.

 

PSU Capacity

Each PSU supports a different load figure.

PSU Type

PSU-S*1

PSU-M*2

PSU-L*3

*1

Available for the KX-TDA100

*2

Available for the KX-TDA100 and KX-TDA200

Available for the KX-TDA200

*3

 

Maximum Load Figure

64

128

512

Installation Manual

37

Page 37
Image 37
Panasonic KX-TDA100 Power Supply Unit Selection, Load Figure Calculation, PSU Capacity, Equipment Type, PSU Type