Panasonic KX-TDA100 LED Indications, Maximum Cabling Distance of Extension Connection, Level

Models: KX-TDA100

1 282
Download 282 pages 61.74 Kb
Page 91
Image 91
BNC (coaxial) Connector (RX)

2.4.7 E1 Card (KX-TDA0188)

BNC (coaxial) Connector (RX)

 

No.

Signal Name

Level [V]

Function

1

1

RX-

(-)

Receive data (-)

2

2

RX+

(+)

Receive data (+)

 

LED Indications

Indication

CARD STATUS

SYNC-ERR

RAI

AIS

SYNC

Colour

Green/Red

Red

Red

Red

Green

Description

Card status indication

OFF: Power Off

Green ON: Normal (all ports are idle)

Green Flashing (60 times per minute): Normal (a port is in use)

Red ON: Fault (includes reset)

Red Flashing (60 times per minute): Out of Service

Non-synchronisation status indication

OFF: Normal

ON: Out of synchronisation

RAI signal status indication

OFF: Normal

ON: Alarm (Clock Slave)

Flashing (60 times per minute): Alarm (Clock Master)

AIS status indication

OFF: Normal

ON: Alarm

Synchronisation status indication

OFF: Not synchronised

ON: Synchronised

Flashing (60 times per minute): Synchronised (Clock Master)

Maximum Cabling Distance of Extension Connection

The maximum length of the extension cable that connects the E1 cards is shown below:

Diameter

Maximum Distance

0.5 mm:

200 m

 

 

Installation Manual

91

Page 91
Image 91
Panasonic KX-TDA100 LED Indications, Maximum Cabling Distance of Extension Connection, BNC coaxial Connector RX, Level