Panasonic KX-TDA100 Specifications, 1.4.1, General Description, Control Bus, Communication Bus

Models: KX-TDA100

1 282
Download 282 pages 61.74 Kb
Page 28
Image 28
Specifications

1.4.1 General Description

1.4

Specifications

 

 

 

 

 

 

1.4.1

General Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Bus

 

 

Original bus (16-bit, 8 MHz, 10 megabytes per second)

 

 

 

 

 

 

 

 

 

 

 

 

Communication Bus

 

 

H.100 bus conformity (1024 time slots)

 

 

 

 

 

 

 

 

 

 

 

 

Switching

 

 

Non-blocking

 

 

 

 

 

 

 

 

 

 

 

 

Power Input

 

PSU-S

 

100 V AC to 130 V AC; 1.4 A/200 V AC to 240 V AC; 0.8 A; 50

 

 

 

 

 

 

Hz/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSU-M

 

100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50

 

 

 

 

 

 

Hz/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSU-L

 

100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A; 50

 

 

 

 

 

 

Hz/60 Hz

 

 

 

 

 

 

 

 

 

 

 

External Battery

 

 

+36 V DC (+12 V DC × 3, recommended maximum capacity is

 

 

 

 

 

 

28 Ah)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Power Failure Tolerance

 

300 ms (without using backup batteries)

 

 

 

 

 

 

 

 

 

 

 

 

Memory Backup Duration

 

7 years

 

 

 

 

 

 

 

 

 

 

 

 

Dialling

 

Trunk

 

Dial Pulse (DP) 10 pps, 20 pps

 

 

 

 

 

 

 

 

Tone (DTMF) Dialling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extension

 

Dial Pulse (DP) 10 pps, 20 pps

 

 

 

 

 

 

 

 

Tone (DTMF) Dialling

 

 

 

 

 

 

 

 

 

 

 

 

Mode Conversion

 

 

DP-DTMF, DTMF-DP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ring Frequency

 

 

20 Hz/25 Hz (selectable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk Loop Limit

 

 

1600 Ω maximum

 

 

 

 

 

 

 

 

 

 

 

 

Operating

 

Temperature

 

0 °C to 40 °C

 

 

 

Environment

 

 

 

 

 

 

 

 

 

 

Humidity

 

10 % to 90 % (non-condensing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conference Call Trunk

 

From 10 × 3-party conference call to 4 × 8-party conference call

 

 

 

 

 

 

 

 

 

 

 

 

Music on Hold (MOH)

 

 

2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)

 

 

 

 

 

 

MOH1: External Music Source port

 

 

 

 

 

 

 

 

MOH2: Selectable Internal/External Music Source port

 

 

 

 

 

 

 

 

 

Paging

 

Internal

 

Level Control: -15 dB to +6 dB in 3 dB steps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

 

2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)

 

 

 

 

 

 

 

 

 

 

Serial Interface Port

 

RS-232C

 

1 (maximum 115.2 kbps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB

 

1

 

 

 

 

 

 

 

 

 

 

 

 

Extension Connection Cable

 

SLT

 

1-pair wire (T, R)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DPT

 

1-pair wire (D1, D2) or

 

 

 

 

 

 

 

 

 

2-pair wire (T, R, D1, D2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APT

 

2-pair wire (T, R, D1, D2)

 

 

 

 

 

 

 

 

 

 

 

28

Installation Manual

Page 28
Image 28
Panasonic KX-TDA100 Specifications, 1.4.1, General Description, Control Bus, Communication Bus, Switching, Power Input