2.9.3 Site Planning

CS Coverage Area

The example below shows the size of the coverage area of 1 CS if it is installed in an area with no obstacles.

Note

Radio signal strength levels are measured during the site survey (refer to "2.9.5 Site Survey").

A Coverage Area

Radio signal strength level is greater than "3".

(About 50 m to 60 m*1)

A

Gray Zone: Conversation will be intermittent

Radio Signal Strength Levels

B

BGood Coverage Area Radio signal strength level is greater than "8". (About 30 m to 40 m*2) Good sound quality can be maintained.

COut of Service:

Cannot make/receive calls

Level: 00

Level: 01 to 02

Level: 03 to 07

Level: 08 to 10

Level: 11 to 12

Out of range

Receives noise easily or disconnects May receive noise

Good

Better

*1 KX-TDA0151CN: About 35 m to 50 m

*2 KX-TDA0151CN: About 20 m to 30 m

Site Survey Preparation

1.Obtain a map and investigate the installation site.

a.Check the obstacles (e.g., shelves, columns, and partitions).

b.Check the materials of the structures (e.g., metal, concrete, and plywood).

c.Check the layout and dimensions of the room, corridor, etc.

d.Write down the above information on the map.

2.Examine the service area required by the user on the map, referring to the following example.

a.Draw the coverage area around a CS. Extend the coverage area 30 m to 60 m in each direction, depending on the materials of the building structures and obstacles in the installation site. Note that a CS cannot be installed outside a building.