D1255RB/D1256RB/D1257RB Installation Instructions 4.0 D1256RB Programming Requirements
4.4.5Keypad (Command Center) Functions
The following keypad function must be enabled or passcode required to enable the [DETECTOR RESET] key.
•#27 Reset Sensors
Include the following items in the menu:
•#9 View Event Memory
•#10 View Point Status
•#12 Fire Test
•#21 View Log
•#29 Remote Program
•#32 Display Rev
Refer to Figure 18.
For the D9412GV2 Control Panel, program each of the keypad functions with E (enabled) and not P (passcode required). If restricting any of the keypad functions with a passcode is required, those functions must be executed from a custom function that includes an authorized passcode.
Example (Refer to Figure 18.): If the keypad function View Memory is programmed as P (passcode required), and the passcode 125600 has authority to execute it, the keystrokes would be:
[A] [4] [0] [1] [2] [5] [6] [0] [0] [E]
When creating a Menu Function List for a keypad address, consider that the D1256RB Keypad does not have numeric keys. Ensure that:
•no
•the CC# Menu Key Lock prompt is set to No for the D1256RB address.
Figure 18: Example – Keypad Functions
| Keypad Functions |
| |
# | Functions | Command | E/P* |
1 | Disarm ? |
| P |
2 | Master Arm Delay ? | CMD 1 | P |
3 | Master Arm Instant ? | CMD 11 |
|
4 | Perimeter Instant ? | CMD 2 | P |
5 | Perimeter Delay ? | CMD 3 | P |
6 | Watch Mode ? | CMD 6 | E |
7 | Perimeter Part ? | CMD 8 | P |
8 | View Area Status ? |
| P |
9 | View Memory ? | CMD 40 | E |
10 | View Pt Status ? |
| E |
11 | Walk Test ? | CMD 44 | E |
12 | Fire Test ? | CMD 58 | P |
13 | Send Report ? | CMD 41/42 | P |
14 | Door Control ? | CMD 46 | P |
| Cycle Door ? |
| E |
| Unlock Door ? |
| E |
| Secure Door ? |
| E |
37 | Access Control Level? |
| P |
15 | Change Display ? | CMD 49 | E |
16 | Change Time/Date ? | CMD 45 | E |
17 | Change Passcode ? | CMD 55 | P |
18 | Add User ? | CMD 56 | P |
19 | Del User ? | CMD 53 | P |
20 | Extend Close ? | CMD 51 | P |
21 | View Log ? |
| E |
22 | Print Log ? |
| P |
23 | User Command 7 ? | CMD 7 | P |
24 | User Command 9 ? | CMD 9 | P |
25 | Bypass a Point ? | CMD 0 | P |
26 | Unbypass a Point ? | CMD 00 | P |
27 | Reset Sensors ? | CMD 47 | E |
28 | Change Relays ? | CMD 54 | P |
29 | Remote Program ? | CMD 43 | P |
30 | Move To Area ? | CMD 50 | P |
32 | Display Rev ? | CMD 59 | E |
33 | Service Walk ? |
| P |
34 | Default Text ? | CMD 57 | P |
35 | Change Skeds ? | CMD 52 | P |
36 | Invisible Walk ? |
| P |
*Keypad Function options: P = Passcode; E = Enabled (no passcode required); Blank = Disabled
12 | Bosch Security Systems, Inc. 8/06 F01U011791B |