Bosch Appliances DVR600 operation manual 3.4Version, Security Systems

Models: DVR600

1 6
Download 6 pages 59.8 Kb
Page 3
Image 3
3.4Version 2.0.1

Security Systems

Product

Document type

Release #

DVR 600 Series

Release notes

V2.0.7

oThis port number is now user selectable.

SAP/Doc number

Release date

2013.02.12

This release includes the following bug fixes were below issues are solved:

In low or unstable network configurations the DVR sometimes block any network user access until the unit was power cycled.

It was not possible to record a tour in G3 domes via DVR.

DVR was losing network gateway in some network applications.

Network connection was not possible immediately after network disconnect.

DVR ID in web pages showed one number higher than set in DVR.

DVR rebooted after a number of smart search actions in web interface.

3.4Version 2.0.1

File name: 600series.bin (2012-03-23)

This release includes the following improvement:

Web browser support for DVR 600 Series on IE9

Option to avoid ICMP ping with Control Center (requires CC release v3.35) o Important note:

In the new firmware you can set the ICMP to On or Off in the local UI menu ‘Network-TCP/IP’

ICMP must set to On to get the DVR connected to a CC version 3.34 or older because in this version of Control Center the ICMP is required

In the new Control Center version 3.35 the ICMP is not required anymore, therefore in this CC version you can set ICMP to Off in the local UI menu ‘Network-TCP/IP’

Email notification with a 10 seconds video clip (10 pictures, iFrame only)

Low bandwidth support by selecting 256/512kbps bandwidth throttle (iFrame only mode when selecting bandwidth of 256 or 512kbps in local UI)

PAL or NTSC video format detection is improved (user will be clearly notified when video format of DVR don’t match with video format of connected cameras).

Improve PTZ handling in full screen (you can select Menu, Search, Export or Exit when PTZ control is active)

Video playback from HDD mounted in other DVR600 (possible to move complete HDD set from one to another DVR600)

Avoid invalid log-on when user ID is used special characters like /:@ (In this firmware these characters are grayed out and cannot be selected)

Give warning/possible to cancel before delete video after video format (NTSC/PAL) change

This release includes the following bug fixes were below issues are solved:

It is possible to use AUX on/off function in Control Center version 3.35

Correct AM/PM setting using export via web when DVR is set in 24h mode

Dome never stop moving if using PTZ control and drag mouse point

Page 3 of 6

Page 3
Image 3
Bosch Appliances DVR600 operation manual 3.4Version, Security Systems