Intellivox DDC Installation Manual Appendix

EN 13

 

 

3.Appendix.

3.1 Reference part list.

Connectors for external wiring.

Terminal

 

Description

 

Manufacturer

 

Manufacturer code

 

 

 

 

 

 

 

RS-485

 

Wago cage clamp connector 5 pin

 

WAGO

231-105/026-000

 

 

female 5 mm pitch

 

 

 

 

 

 

 

 

 

 

Audio input

 

Wago cage clamp connector 6 pin

 

WAGO

 

231-106/026-000

 

 

female 5 mm pitch

 

 

 

 

 

 

 

 

 

 

 

Failure, Fan, Ambient

 

Wago cage clamp connector 5 pin

 

WAGO

231-605

SPL and Temperature

 

male 5 mm pitch

 

 

 

 

 

 

 

 

 

 

 

Table 3 Intellivox external connectors details.

Other installation related accessories.

Description

 

Type Number

 

 

 

Intellivox swivel bracket 90°

 

LBC 3270/00

 

 

 

Intellivox swivel bracket 45°

 

LBC 3271/00

 

 

 

Ambient mic. and temperature sensor

 

LBC 3262/00

 

 

 

Table 4 Specific installation related accessories.

2.Reduction of RF emission. Although the Intellivox electronics module is well shielded and external connections are de-coupled to prevent RF emission from the internal high speed digital circuits, this protection will not work properly when the chassis has no solid ground reference.

3.Immunity. The GND terminal shorts currents which are induced by (RF) fields in the signal cables effectively to chassis-ground, provided that the cable shield is of sufficiently low impedance.

Other network related accessories.

Description

 

Type Number

 

 

 

Program set

 

LBC 3260/00

(Adapter cable+RS-232 to RS-485

 

 

adapter+ WinControl CD-Rom)

 

 

 

 

 

Table 5 Specific network related accessories

3.2 Grounding strategy.

The ground (GND) terminals on the electronics module serve different purposes.

1.Safety. The GND terminal located at the mains IEC connector provides a direct low impedance path from the metal parts of the chassis to ground. In conjunction with a proper designed mains distribution network, this offers extra safety in situations where the standard class 2 insulation is not sufficient (fire, moisture etc.). Always connect the IEC ground terminal.

To make things even more complex, the RS-485 terminal of the chassis also has a DGND pin, while the ambient SPL/temperature terminal has both GND and AGND pins.

The pins labeled GND are connected directly to the chassis.

The RS-485 DGND pin is not a ground pin, but serves as a reference for the RS-485 AB and YZ wires. Although the DGND pin should be connected to the shielding of the RS-485 cable (when in use), DGND (and ABYZ) has no relation to GND except for the fact that the voltage between DGND and GND is clamped to a maximum voltage of 50 V for reasons of safety and immunity. In an installation with a connected network, the RS-485 cable shield must be grounded at some central position.

DGND should not be connected to any other ground pin (GND or AGND) on the chassis.

Bosch Security Systems July 2003

Page 12
Image 12
Bosch Appliances LBC 325X installation manual Reference part list, Grounding strategy