Intellivox DDC Installation Manual Installation Guide | EN 11 |
|
|
hexagonal nut. The swivel brackets are mounted to the rear of the enclosure by four M5 pan head screws (factory supplied). Refer to Table 4 in chapter 3.1 for ordering information.
3.The third method is to mount the column directly to a wall or a dedicated mounting panel by means of spacers and screws through the mounting surface. In this case extra attention should be paid to the following aspects:
•The threaded inserts are M5 metric and the depth is 16 mm.
•It is advised to keep the rear side of the Intellivox free from the wall in order to prevent unwanted resonances.
2.5.2. Measures and dimensions.
As mentioned earlier all enclosure dimensions refer to the
Fig 7 LBC 3253/00 Intellivox-2c dimensions, all measures in mm
Bosch Security Systems July 2003