LTC 5104, LTC 5108 Series Instruction Manual Installation

 

EN 12

 

 

 

 

4.15 Status Line

4.17

Screen Display Position

This menu determines what will be displayed on the on-screen Status Line. There are three options: 1. A full status line, which contains the camera number, camera title, sequence mode, and alarm status information, 2. Camera number and title only, or 3. Nothing at all (see SCREEN 9). SKIP/clr toggles the selection pointer of the modes. The default is a full status line.

The display may be positioned both horizontally and vertically (see SCREEN 11). The numeric 1 key is used to move the display up, 2 to move down, 3 to move left and 4 to move right. The default is bottom center of the monitor screen.

Screen 11

4.18 Programming Camera Titles

Screen 9

CAUTION: Selecting the status line option other than the full status does not display the word ALARM on the video.

With video present, access the Title Programming menu by pressing and holding RUN/next then pressing the numeric 3 key (see SCREEN 12).

4.16Screen Display Brightness and Background

The display brightness may be adjusted over seven levels from black to white (see SCREEN 10). The display background may be selected as silhouette (profile), no silhouette (no profile), or block format. Use SKIP/clr to make the display lighter, and ALARM darkens the display. When the end of the brightness range has been reached, the background format will toggle. The default background is silhouette.

Screen 12

Once in the title setting screen:

• To call up and program the title for a particular

 

camera, enter the desired camera number via

 

the numeric keys. This displays the entered

 

camera # on all monitors (if video present).

 

• To move the cursor on the title screen, press

 

RUN/next.

 

• To increment characters, press ALARM.

 

• To decrement characters, press SKIP/clr.

Screen 10

• To exit, press DWELL.

 

 

 

Bosch Security Systems 7 April 2004

Page 12
Image 12
Bosch Appliances LTC 5108, LTC 5104 instruction manual Status Line Screen Display Position, Programming Camera Titles