24 en Installation

FlexiDomeHD 1080p IP Camera

 

 

5.3Connections

5.3.1Make the connections

The unit has connection terminals on flying leads. In wet or outdoor installations make use of a field wiring box with NEMA Type 4X or IP66 protection level or better. Make the connections inside a water tight compartment. After connections are made ensure that the watertight compartment is tightly closed and cables and conduits are properly sealed to prevent ingress of water.

Cable tree

Use the following table to identify the wires in the cable tree:

Wire color

AWG

Signal

 

 

 

 

 

 

 

 

Red

26

+12 VDC / 24 VAC

 

 

 

 

 

 

 

 

Brown

26

-12 VDC / 24 VAC

 

 

 

 

 

 

 

 

Yellow / Green

24

Earth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black / Orange

28

Alarm Out A

 

 

 

 

 

 

 

 

White / Orange

28

Alarm Out B

 

 

 

 

 

 

 

 

White / Violet

28

Ground (Alarm In + Data)

 

 

 

 

 

 

 

 

Orange / Violet

28

Alarm In 1

 

 

 

 

 

 

 

 

Violet

28

Alarm In 2

 

 

 

 

 

 

 

 

White

28

Audio In

 

 

 

 

 

 

 

 

(Shield)

28

Ground (Audio In)

 

 

 

 

 

 

 

 

Black

28

Audio Out

 

 

 

 

 

 

 

 

(Shield)

28

Ground (Audio Out)

 

 

 

 

 

 

 

 

Blue

28

Data CTS (Rx-)

 

 

 

 

 

 

 

 

Blue / White

28

Data RTS (Tx+)

 

 

 

 

 

 

 

 

Grey

28

Data RXD (Rx+)

 

 

 

 

 

 

 

 

Grey / White

28

Data TXD (Tx-)

 

 

 

 

 

 

 

 

Note:

For connections use wires of at least the same thickness.