Installation Instructions

Models: NES 730, NES 930

Table of Contents

NOTE: The blocked letters, such as A, shown below, refer to illustrations on

Pages 2 & 4. Match these to the related text pages.

Overall Dimensions A

2

Power Supply B

2

Cabinet Preparation and Clearances C

2, 3

Junction Box Location D

2

Countertop Cutout Dimensions E

2

Installing the Cooktop F

3-4

Secure Cooktop to Countertop G

3-4

Solid Surface Countertop Installations H and I

4-5

Electrical Connection

5

IMPORTANT: Save these instructions for Local Electrical Inspector’s use. INSTALLER: Please leave these Installation Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

READ AND SAVE THESE INSTRUCTIONS

OVERALL DIMENSIONSA

See Illustration A, Page 2. These dimensions are overall.

POWER SUPPLY

B

ELECTRICAL POWER CONNECTION FOR COOKTOP

Power Supply is dual rated: 240 Volts or 208 Volts, 4 wire, 60 Hz, with the following circuit breaker requirements: Model NES 730 at 30 Amps; Model NES 930 at 40 Amps

Connect only to a 4-wire 120/240 or 120/208 volt ac system. The neutral is required for the operation of this appliance and an independent ground is required.

Install a junction box (not supplied), below the counter top within 3 feet of flexible conduit (supplied) located at the left rear corner of the cooktop rough-in box.

JUNCTION BOX LOCATION D

Plan the installation of the unit so that the location of the junction box is within 3 feet of the left rear of the cooktop bottom. It must be accessible

from the front of the cabinet.