2.4.3Rear panel

Plena Easy Line Mixer Installation and User Instructions Description

en 12

2.4.3Rear panel

See figure 2.3 for an overview of the connectors and switches:

1Microphone/line 1 input with trigger, Euro style pluggable screw terminal connector - DIP switch settings for: chime, PTT (push to talk), mic/line, speech filter, and phantom power (see number 3). Input is wired in parallel with microphone/line 1, XLR connector (see number 2).

2Microphone/line 1 input, XLR connector - DIP switch settings for: chime, PTT (push to talk), mic/line, speech filter, and phantom power (see number 3). Input is wired in parallel with microphone/line 1, Euro style pluggable screw terminal connector (see number 1).

3 DIP switch for microphone/line 1 and microphone/ line 2 (see numbers 1 and 2, and 4 respectively).

4 Microphone/line 2 input, XLR connector - DIP switch settings for speech filter, mic/line, VOX, and phantom power (see number 3).

5Microphone/line 3 input, XLR connector - DIP switch settings for mic/line, and phantom power (see number 6).

6DIP switch for microphone/line 3 and microphone/ line 4 (see numbers 5 and 7 respectively).

7 Microphone/line 4 input, XLR connector - DIP switch settings for mic/line, and phantom power (see number 6).

8 Microphone/line 5 input, XLR connector - DIP switch settings for mic/line, and phantom power (see number 9).

9 DIP switch for microphone/line 5 and microphone/ line 6 (see numbers 8 and 10 respectively).

10Microphone/line 6 input, XLR connector - DIP switch settings for mic/line, and phantom power (see number 9).

11Mains voltage switch, C13 - 115/230 VAC 50/60 Hz.

12Tel. emergency/100V input, Euro style pluggable screw terminal connector - VOX function. This input has highest priority.

13Telephone emergency/100V input volume control - control range -25 dB to 0dB (see number 12).

14Chime volume control for microphone/line input 1 (see numbers 1 and 2).

15Ducking level control for microphone/line inputs 1 and 2.

16Call station input, RJ-45 connector - PLE-2CS or PLE-2CSMM, chimes are in call station. This input has second highest priority.

17Remote control wall-panel-input, RJ-45 connector. Wall panel incorporates: BGM source selection, and zone on/off control.

18Music input (number 1 disc), 2x RCA/cinch connectors. Stereo, summed mono.

19Music input (number 2 radio), 2x RCA/cinch connectors. Stereo, summed mono.

20Music input (number 3 auxiliary), 2x RCA/cinch connectors. Stereo, summed mono.

21Pre-out, amp in insert, 2x RCA/cinch connector - can be used for EQ or feedback suppressor.

22Master switch for line out or music (see number 23).

23Music master output, XLR connector - switch setting for line out, or music only (see number 22).

24Volume override output and 24 VDC input:

Volume override output - Euro style pluggable screw terminal connector.

24 VDC backup power input - Euro style pluggable

screw terminal connector.

25Zone 1 output, XLR connector, balanced.

26Zone 2 output, XLR connector, balanced.

27Mains fuse.

28Earth connection screw.

Note

The unit must be earthed.