Small Size LCD/LED Monitors

Navigating the Monitor en 35

 

 

 

 

Trigger

Enables or disables the Trigger function, and configures the trigger

 

settings when enabled:

 

 

Trigger Enable: Turns the Trigger function On of Off.

 

Trigger Input: Selects the input signal source to display when a

 

trigger signal is received.

 

 

Buzzer: Turns the trigger buzzer tone On or Off.

 

Trigger Time: Sets the time duration the trigger input (as set by the

 

Trigger Input function) is displayed. Once the time expires, the

 

monitor will automatically switch back to the last viewed input.

 

Trigger Option: sets the trigger signal type to N/C (normal closed),

 

N/O (normal opened), High (2~5V) or Low (0~0.6V).

 

 

Auto Switching

Enables or disables the auto switch function that allows the monitor

 

to automatically switch to and display an available input signal.

 

 

Firmware Version

Displays the release level of the monitor firmware.

 

 

 

 

 

 

NOTICE!

When key lock is enabled through the front panel, use the front panel buttons to disable the key lock command. To disable the key lock feature using the front panel buttons, press and hold both the Input and the Menu buttons until the monitor displays the Key Unlocked message.