4 Installation

4.1 Preparations

The VIP X1600 B base is designed for installation in a switch cabinet. Mounting the unit in a 19-inch rack using the installation material supplied is a quick and easy operation.

It is also possible to operate this as a desktop unit. The four elastic bumpers included in the scope of delivery ensure a non-slip support.

CAUTION!

The unit is designed for indoor operation.

Select a suitable location for installation that guarantees to meet the environmental

!conditions. The ambient temperature must be between 0 and +50 °C (+32 and +122 °F). The relative humidity must not exceed 95% (non-condensing).

The VIP X1600 B generates heat during operation. During installation, please note the maximum heat value of 170 BTU/h. Ensure that there is adequate ventilation and enough clearance between the unit and heat-sensitive objects or equipment.

Please ensure the following installation conditions:

Do not install the unit close to heaters or other heat sources. Avoid locations exposed to direct sunlight.

Allow sufficient space for running cables.

Ensure that the unit has adequate ventilation. Bear the total heat output in mind, particularly when installing multiple units in a switch cabinet.

When making connections, use only the cables supplied or use appropriate cables immune to electromagnetic interference.

Position and run all cables so that they are protected from damage, and provide adequate cable strain relief where needed.

Avoid impacts, blows and severe vibrations, as these can irreparably damage the unit.

4.2 Installing Modules

Installation of the different modules in the VIP X1600 B base is described in the relevant Quick Installation Guides and the Installation and Operating Manuals. It is also possible to install, remove and exchange modules during operation.

CAUTION!

!Ensure that Slot 1 is always populated by a module, even when modifying the installation. Malfunctions may occur when the VIP X1600 B is switched on without a functional module in Slot 1.