For questions or replacement brushes, please call Dremel’s Consumer Service at
or check our website at www.Dremel.com. 4. Install existing or new brushes so the curved surface of the brush end match- es the curvature of the motor commuta- tor (as seen through the brush opening). NOTE: The detent on the brass clip must fit into the slot on the side of the brush pocket, which secures the brass clip in the proper
position (Figure C).
5. Reinstall brush covers by angling the
6. Plug power cord into a wall outlet. Run the rotary tool at full speed for 5 minutes under no load. This will properly seat the brushes and extend the life of the tool.
Cleaning The Tool
Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not attempt to clean by inserting pointed objects through openings.
The tool may be cleaned with com- pressed air. Always wear safety goggles when cleaning tool
with compressed air. There is no need to lubricate the Dremel™ rotary tool.
! CAUTION Certain cleaning agents and solvents will damage plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated clean- ing solvents, ammonia and household detergents that contain ammonia.
Clean the “soft grip” areas of the tool using a damp cloth. Tougher soiled areas may require more than one wipe application to get clean.
15