Wiring

Connecting the wires

The CC-16 zone controller uses a standard 6-wire Eurostyle terminal block for power and network connections.

1.Connect the network cable to the RS-485 A/B pins on the ESP-88. Note which wire is connected to A and B.

2.Connect the network cable to the CC-16 terminal blocks. Ensure the wire connected to “A” on the ESP-88 is the same one connected to “A” on the controllers and that the “B-wire” is connected to “B” on the controllers. Connect Shield to the RS-485 cable shield if necessary.

3.Connect the power supply to the Ground and Vin+ terminals on the controllers.

Wiring Example