Installation
Maximum cable distances
Wire Gauge/ |
| Number of |
| |
Power Supply Voltage | 1 | 2 | 4 | 15 |
24 AWG 18V | 2000 ft (610 m) | 1852 ft (564 m) | 926 ft (282 m) | 247 ft (75 m) |
|
|
|
|
|
24 AWG 12V | 1481 ft (451 m) | 741 ft (226 m) | 370 ft (113 m) | 99 ft (30 m) |
|
|
|
|
|
24 AWG 9V | 370 ft (113 m) | 185 ft (56 m) | 93 ft (28 m) | 25 ft (7 m) |
|
|
|
|
|
18 AWG 18V | 2000 ft (610 m) | 2000 ft (610 m) | 2000 ft (610 m) | 1010 ft (308 m) |
|
|
|
|
|
18 AWG 12V | 2000 ft (610 m) | 2000 ft (610 m) | 1515 ft (461 m) | 404 ft (123 m) |
|
|
|
|
|
18 AWG 9V | 1515 ft (461 m) | 758 ft (231 m) | 379 ft (115 m) | 101 ft (31 m) |
|
|
|
|
|
Installing the mounting box
Install a
Select a place that is convenient for the people who will be controlling the system. We suggest mounting the unit at
CAUTION: Do not install the
CAUTION: Do not place the power or network cables in the same conduit with the mains wire, unless you are sure that special regulatory insulation requirements are met. Consult your local electrical regulatory agency for further information.
8