The following chart shows examples of the types of loads possible and the mode required:
Intended Loudspeaker Load Number of Affected Channels Power Rating Max Channels Output Mode
2 to 16 Ohms 1500 W @ 4Ω8Mono
4 to 8 Ohms 21000 W @ 8Ω4V-Bridge (Low-Z)
70-V “constant voltage” lines 2800 W @ 70V 4V-Bridge (70V)
100-V “constant voltage” lines 21000 W @ 100V 4V-Bridge (100V)
2 Ohms requiring high current 21000 W @ 2Ω4I-Share (Low-Z)
4 Ohms requiring high power 42000 W @ 4Ω2Quad (Low-Z)
70-V “constant voltage” lines 41600 W @ 70V 2Quad (70V)
100-V “constant voltage” lines 42000 W @ 70V 2Quad (100V)
Note: Configure the output mode of the amplifier before connecting loudspeakers. See page 24 for details on front panel configuration.
Carefully follow the proper connection method for the selected output configuration.
The wiring of the connector varies by amplifier output configuration. The output pin assignments for Mono (single channel) and V-bridge
configurations are printed on the rear panel of the amplifier. The following graphics illustrate wiring examples for the different output
configuration modes.
Figure 8. output wiring showing the four basic configurations