BOULDERLINK MESSAGESEach component in the system can send a message to the 1012 which 
is then shown  on its  display. This is particularly  helpful in  confirming 
the operating  status  of  each  power  amplifier  in a  multiple  amplifier 
system.
“AMPLIFIER 1  ERROR” means  that an internal  power supply  has 
failed and the amplifier has turned itself off to protect the speakers from 
damage.
“AMPLIFIER 1 HAS DC” means that it has turned itself  off due to a 
DC offset voltage being detected at its inputs.
“AMPLIFIER 1 IS HOT” means  that is has turned  itself off due to a 
higher than normal temperature condition on the heatsinks.
“AMPLIFIER  CLIP”  means  that  the  amplifier’s  output  has 
momentarily reached its voltage limitation.
BOULDER
LINK
5-4