MAINTENANCE

WARNING TEMP. INDICATOR

The WARNING TEMP. indicator flashes red when an internal temperature of the projector exceeds the normal temperature. The projector cannot be turned on while the WARNING TEMP. indicator is flashing with the READY indicator off. When the temperature inside the projector returns to normal, the READY indicator lights green. Then you can turn the projector back on. The WARNING TEMP indicator stops flashing after turning the projector on. If the WARNING TEMP indicator continues to flash after turning the projector back on, check the items listed below.

1

Ventilation slots of the projector may be blocked. In such an

TOP CONTROL

event, reposition the projector so that the Ventilation slots cannot

 

be obstructed.

2

The Air filter may be clogged with dust particles. Clean the Air

filter by following the section "AIR FILTER CARE AND

 

CLEANING" below.

3

If the WARNING TEMP. indicator remains on after performing

the above checks, the Cooling fans or the internal circuits may

be malfunctioning. In that case, call Boxlight at 1-800-762-5757 or 360-779-7901 for service.

 

G

RNIN

WA

P.

TEM

 

 

 

P

 

 

M

 

 

A

 

 

 

E

L

 

 

 

 

 

 

 

 

C

 

 

 

A

 

 

 

L

 

 

 

P

 

 

 

E

 

 

 

 

R

 

 

 

 

 

VOLUME –

Warning Temp. indicator

AIR FILTER CARE AND CLEANING

Removable Air Filter prevents dust from accumulating on the surface of the Projection Lens and Projection Mirror. Should the Air Filter become clogged with dust particles, it will reduce Cooling Fans’ effectiveness and may result in internal heat build up and adversely affect the life of the projector. Clean the Air Filter following the steps below:

1

Turn off the projector, and disconnect AC power cord from the

 

AC outlet.

2

Turn the projector upside down and remove the Air Filter by

 

pulling the latches upward.

3

Clean the Air Filter with a brush or wash out dust and particles.

4

Replace the Air Filter properly. Make sure that the Air Filter is

 

fully inserted.

CAUTION

Do not operate the projector with the Air Filter removed. Dust may accumulate on the LCD Panel and the Projection Mirror degrading picture quality.

Do not put small parts into the Air Intake Vents. It may result in malfunction of the projector.

AIR FILTER

Pull up and remove.

RECOMMENDATION

We recommend avoiding dusty/smoky environments when operating a projector. Usage in these environments may cause poor image quality.

When using under dusty or smoky conditions, dust may accumulate on a lens, liquid crystal panels, or optical elements inside the projector. This condition may degrade the quality of a projected image.

When the above symptoms are noticed, contact Boxlight at 1-800-762-5757 or 360-779-7901 for proper cleaning.

CLEANING PROJECTION LENS

Follow these steps to clean the Projection Lens:

1

Apply a non-abrasive camera lens cleaner to a soft, dry cleaning cloth. Avoid using an excessive amount of cleaner.

 

Abrasive cleaners, solvents or other harsh chemicals might scratch a surface.

2

3

Lightly wipe a cleaning cloth over the Projection Lens.

When the projector is not in use, replace the Lens Cover.

41