BOXLIGHT CP-322I Command data chart continued, CP-S318/328W/TECHNICAl責了 03.5.27 239 PM ページ

Models: CP-322I

1 54
Download 54 pages 26.67 Kb
Page 49
Image 49
Command data chart (continued)

CP-S318/328W/TECHNICAl責了03.5.27 2:39 PM ページ 8

Command data chart (continued)

Names

Operation type

 

Header

 

 

 

 

 

 

 

 

 

Command data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRC

Action

 

Type

Setting code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.Position Reset

 

Execute

BE EF

03

06

00

IC D3

06

00

 

03

70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.Size Reset

 

Execute

BE EF

03

06

00

68

D2

06

00

 

04

70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Color Balance

 

Execute

BE EF

03

06

00

94

D3

06

00

 

05

70

00

00

R Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Color Balance

 

Execute

BE EF

03

06

00

D0 D3

06

00

 

06

70

00

00

B Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sharpness Reset

 

Execute

BE EF

03

06

00

C4 D0

06

00

 

09

70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Color Reset

 

Execute

BE EF

03

06

00

80

D0

06

00

 

0A 70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tint Reset

 

Execute

BE EF

03

06

00

7C D1

06

00

 

0B 70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keystone_V Reset

 

Execute

BE EF

03

06

00

08

D0

06

00

 

0C 70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keystone_H Reset

 

Execute

BE EF

03

06

00

98

D8

06

00

 

20

70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto Adjust

 

Execute

BE EF

03

06

00

91

D0

06

00

 

0A 20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Time Reset

 

Execute

BE EF

03

06

00

58 DC

06

00

 

30

70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Filter Time Reset

 

Execute

BE EF

03

06

00

98

C6

06

00

 

40

70

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

off

BE EF

03

06

00

FB D8

01

00

 

20

30

00

00

Blank on/off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on

BE EF

03

06

00

6B D9

01

00

 

20

30

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

C8 D8

02

00

 

20

30

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF

03

06

00

D9 D8

02

00

 

20

60

00

00

 

 

 

 

(Example of Return)

 

 

 

 

 

 

 

 

 

 

 

 

Error Status

 

 

Get

00 00

01 00

 

 

 

02 00

 

03 00

 

 

 

 

 

(Normal)

(Cover-error)

(Fan-error)

(Lamp-error)

 

 

 

 

 

 

 

 

 

 

 

 

04 00

05 00

 

 

 

06 00

 

 

07 00

 

0800

 

 

 

 

 

(Temp-error) (Air flow-error)

(Lamp-Time-over) (Cool-error)

(Filter-Error)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

OFF

BE EF

03

06

00

2A D3

01

00

 

00

60

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

ON

BE EF

03

06

00

BA D2

01

00

 

00

60

01

00

 

 

 

 

 

 

Get

BE EF

03

06

00

19

D3

02

00

 

00

60

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB1

BE EF

03

06

00

FE D2

01

00

 

00

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB2

BE EF

03

06

00

3E D0

01

00

 

00

20

04

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Source

Set

 

Video

BE EF

03

06

00

6E D3

01

00

 

00

20

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SVideo

BE EF

03

06

00

9E D3

01

00

 

00

20

02

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Component

BE EF

03

06

00

AE D1

01

00

 

00

20

05

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

CD D2

02

00

 

00

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

31

D3

02

00

 

01

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volume

 

Increment

BE EF

03

06

00

57

D3

04

00

 

01

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Decrement

BE EF

03

06

00

86

D2

05

00

 

01

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

Normal

BE EF

03

06

00

46

D3

01

00

 

02

20

00

00

Mute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mute

BE EF

03

06

00

D6 D2

01

00

 

02

20

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

75

D3

02

00

 

02

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Get

BE EF

03

06

00

89

D2

02

00

 

03

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brightness

 

Increment

BE EF

03

06

00

EF D2

04

00

 

03

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Decrement

BE EF

03

06

00

3E D3

05

00

 

03

20

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Page 49
Image 49
BOXLIGHT CP-322I user manual Command data chart continued, CP-S318/328W/TECHNICAl責了 03.5.27 239 PM ページ