Brada Appliances YPM-06C Trouble Shooting, Appendixppe, Air-conditioner, Technical parameters

Models: YPM-06C

1 14
Download 14 pages 43.7 Kb
Page 14
Image 14
TROUBLE SHOOTING

TROUBLE SHOOTING

Please check the air conditioner by yourself referring to the following chart before contacting professional service.

Trouble

Reason

Solution

 

Is no power supply?

Plug in and turn on the unit.

The unit doesn’t

Is water full?

Drain out the water and restart the unit.

 

Please use only

when the room

work

Is the room temperature too high?

temperature between 5-40

 

 

 

Is Timer function activated?

Cancel Timer function

 

Is the unit in direct sunlight?

Draw the curtains

 

 

Is the door or window opened? Is

Close the window and door. Turn off or

The unit does

there any heat source in the room?

move the heat source.

not seem to

Is the filter very dirty?

Clean or change the air filter

perform.

Is air inlet outlet blocked?

Clear out the blockage.

 

Is the room temperature lower than

Adjust the setting temperature

 

setting temperature?

 

 

 

The unit noise is

Is the unit not on flat place?

Put the unit on flat and hard

high

place

 

 

 

Compressor

Is overheat protection of compressor

Re-start the unit after 3 minutes when

the temperature

of compressor is

doesn’t work

activated?

reduced.

 

 

 

 

Remote control

Is the distance too far from the unit?

Use remote control near the unit and

Is the signal not received by unit?

make sure it aims at the remote control

doesn’t work

receiver on the unit.

 

 

 

 

Is the battery exhausted?

Change new battery.

NOTE: Stop running the unit and pull out the plug if the problem is beyond the trouble shooting chart, and call service center for help. Don’t repair or disassemble the unit by yourself to avoid any damage.

APPENDIXPPE IX

Technical parameters

 

 

 

Air-conditioner

Serial No. ****

 

 

 

MODEL

YPM-06C

 

 

 

RATED COOLING

5000BTU

 

 

 

REFRIGERANT/CHARGE

R410a/260g

 

 

 

POWER SUPPLY

110-120V/60Hz

 

*******

 

RATED CURRENT

7.5A

Conforms to UL STD. 484

HIGH/LOW PRESSURE

3.5/1.0MPa

Certified to CSA STD. C22.2 No.92

NOISE

54dB (A)

 

 

 

NET WEIGHT

19kg

YOAU ELECTRIC CO.,LTD

DIMENSION(L*D*H)

310*296*850mm

Motor-Compressor Thermally Protected

 

Risk of electric shock. Disconnect Power before Servicing Unit

There is no further notice for the change of the parameters above, please refer the exact parameters base on the rating plate

*Do not dispose this product as unsorted municipal waste. Have refrigerant removed by a qualified service technician before disposing of this unit .

- 14-