TROUBLE SHOOTING
Please check the air conditioner by yourself referring to the following chart before contacting professional service.
Trouble | Reason | Solution | ||
| Is no power supply? | Plug in and turn on the unit. | ||
The unit doesn’t | Is water full? | Drain out the water and restart the unit. | ||
| Please use only | when the room | ||
work | Is the room temperature too high? | |||
temperature between | ||||
|
| |||
| Is Timer function activated? | Cancel Timer function | ||
| Is the unit in direct sunlight? | Draw the curtains |
| |
| Is the door or window opened? Is | Close the window and door. Turn off or | ||
The unit does | there any heat source in the room? | move the heat source. | ||
not seem to | Is the filter very dirty? | Clean or change the air filter | ||
perform. | Is air inlet outlet blocked? | Clear out the blockage. | ||
| Is the room temperature lower than | Adjust the setting temperature | ||
| setting temperature? | |||
|
|
| ||
The unit noise is | Is the unit not on flat place? | Put the unit on flat and hard | ||
high | place |
| ||
|
| |||
Compressor | Is overheat protection of compressor | |||
the temperature | of compressor is | |||
doesn’t work | activated? | |||
reduced. |
| |||
|
|
| ||
Remote control | Is the distance too far from the unit? | Use remote control near the unit and | ||
Is the signal not received by unit? | make sure it aims at the remote control | |||
doesn’t work | receiver on the unit. |
| ||
|
| |||
| Is the battery exhausted? | Change new battery. |
NOTE: Stop running the unit and pull out the plug if the problem is beyond the trouble shooting chart, and call service center for help. Don’t repair or disassemble the unit by yourself to avoid any damage.
APPENDIXPPE IX
Technical parameters
|
|
|
| Serial No. **** |
|
|
| MODEL | |
|
|
| RATED COOLING | 5000BTU |
|
|
| REFRIGERANT/CHARGE | R410a/260g |
|
|
| POWER SUPPLY | |
| ******* |
| RATED CURRENT | 7.5A |
Conforms to UL STD. 484 | HIGH/LOW PRESSURE | 3.5/1.0MPa | ||
Certified to CSA STD. C22.2 No.92 | NOISE | 54dB (A) | ||
|
|
| NET WEIGHT | 19kg |
YOAU ELECTRIC CO.,LTD | DIMENSION(L*D*H) | 310*296*850mm | ||
|
|
Risk of electric shock. Disconnect Power before Servicing Unit
There is no further notice for the change of the parameters above, please refer the exact parameters base on the rating plate
*Do not dispose this product as unsorted municipal waste. Have refrigerant removed by a qualified service technician before disposing of this unit .