Bradford-White Corp Convection Heater instruction manual General Operation

Models: Convection Heater

1 28
Download 28 pages 42.14 Kb
Page 17
Image 17
GENERAL OPERATION

GENERAL OPERATION

Manual backgroundWARNING

Water heaters are heat producing appliances. To avoid damage or injury there shall be no materials stored against the water heater or vent-air intake system, and proper care shall be taken to avoid unnecessary contact (especially by children) with the water heater and vent-air intake system.

UNDER NO CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER OR VENT-AIR INTAKE SYSTEM.

TO FILL THE WATER HEATER

 

1. Close the water heater drain valve by turning the knob clockwise

.

2.Open the cold water supply shut-off valve.

3.Open several hot water faucets to allow air to escape from the system.

4.When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check for water leaks at the water heater drain valve, combination temperature and pressure relief valve and the hot and cold water connections.

TO DRAIN THE WATER HEATER

Should it become necessary to completely drain the water heater, make sure you follow the steps below:

1.

Rotate the thermostat dial counter-clockwise

to the lowest possible

 

position.

 

 

2.

Rotate gas control knob clockwise

to the “OFF” position.

3.Shut off the gas supply to the water heater.

4.Close the cold water supply shut-off valve.

5.Open the drain valve on the water heater by turning the knob counter-

clockwise Manual backgroundManual backgroundManual background . The drain valve has threads on the end that will allow the connection of a standard hose coupling.

6.Open a hot water faucet to allow air to enter the system. To refill the water heater, refer to “To Fill the Water Heater.”

17

Page 17
Image 17
Bradford-White Corp Convection Heater instruction manual General Operation