Bradford-White Corp Electric Instantaneous Water Heaters Flow Controlled Single Phase, 1034

Models: Electric Instantaneous Water Heaters

1 6
Download 6 pages 47.66 Kb
Page 3
Image 3
Flow Controlled (Single Phase)

Electric Instantaneous Water Heaters 1034"

Flow Controlled (Single Phase)

Model

kW

Voltage

AMPS

 

Temperature Rise °F

 

Recommended

 

Number

Rating

 

 

0.5

0.75

1.0

1.5

2.0

Wire Size

 

 

 

 

GPM

GPM

GPM

GPM

GPM

 

 

 

EFC-5500-4-S-10

5.5

240

23.0

75

50

38

25

18

10

AWG

 

EFC-6500-4-S-10

6.5

240

27.0

88

59

44

30

22

10

AWG

EFC-7500-4-S-10

7.5

240

32.0

68

51

34

25

8

AWG

 

EFC-9500-4-S-10

9.5

240

40.0

86

65

43

32

8

AWG

EFC-8300-2-S-10

8.3

208

39.0

76

57

38

29

8

AWG

 

Turn on 0.5 GPM (up to 6.5kW)

Turn on 0.7 GPM (7.5 kW and up)

Max Flow 2.0 GPM

Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.

Refer to Voltage Identification Code Chart on page 5.

Applications: Single Phase Only.

Kitchen Sinks, Bar Sinks, Dual Lavs, Utility Sinks, Manufacturing Facilities, and Modular Buildings.

Specifications:

Dimensions: 1034" x 514" x 278"

Weight: 3 lbs. Materials:

Cover: ABS UL rated 94Vo.

Glass reinforced “UDEL†” Heater Body and Ni Chrome Element

Color: White

Standard temperature range 100°F-140°F.

Maintains accurate temperature control

±1°F

Element: Replaceable cartridge insert

Pipe-Fittings: 1/2" NPT compression at bottom of unit.

Operating Pressure: Min 25 PSI, Max 150 PSI.

514"

1034"

278"

934"

OUTLET

INTLET

 

112"

34" 278"

Series Two - Thermostatic (Single Phase)

(Twin Module) With Single Thermostatic Control

 

 

 

 

 

 

 

 

 

Model

kW

Voltage

AMPS

Temperature Rise °F

Recommended

Number

Rating

 

 

1.5

2.0

2.5

3.0

Wire Size

 

 

 

 

GPM

GPM

GPM

GPM

 

 

 

 

 

 

 

 

 

 

EFT-19000-4-D-10

19.0

240

80 (2 x 40 Amps)

87

65

52

43

8 AWG per module

The unit must have 2 independent electrical circuits using correctly rated wire and 2 circuit breakers.

SPEC OPTIONS:

Multi Lavs = ML 0.5 turn on set temp.

Set Temp = 105°F.

Activated in stages based on demand

Min. flow 0.7 GPM Max Flow 3.0 GPM

Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.

Refer to Voltage Identification Code Chart on page 5.

Applications: Single Phase Only.

Residential-Single Shower (Cabin or Condo), Multi Lavs.

9"

Specifications: Dimensions: 10" x 9" x 3" Weight: 8 lbs.

Materials:

Cover: Enameled Steel.

Glass reinforced “UDEL†” Heater Body and Ni Chrome Element Color: White

Element: Dual replaceable cartridge inserts Pipe-Fittings: 3/4" NPT pipe fittings at the bottom of the unit. Operating Pressure: Min 25 PSI, Max 150 PSI.

10"

 

4"

3"

ELECTRICAL

 

SUPPLY

3

Page 3
Image 3
Bradford-White Corp Electric Instantaneous Water Heaters warranty Flow Controlled Single Phase, 1034, 278 934