Light Duty Through-The-Wall
Commercial Gas Water Heater
C
|
| B |
|
| A |
H |
| J |
|
| |
|
| D&G |
| E | F |
|
|
Light Duty Models
|
|
|
|
|
|
| Recovery |
|
| A |
|
| B |
|
| C |
|
|
| D |
| E |
| F | G | H |
|
| J |
|
| ||
|
|
|
|
|
|
|
| Floor |
|
|
|
|
|
|
|
| Floor | Floor | Fl. to | Fl. to |
|
|
|
|
|
| |||||||
NATURAL GAS |
|
|
|
|
| 56°C. Rise/ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
| to |
|
|
|
|
|
|
|
|
| to | to | Space | Space | Fl. to |
| Fl. to | Approx. | |||||||||
|
|
|
|
| 100°F. Rise** |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
| Imp. | U.S. |
|
|
|
| Flue |
| Jacket |
| Vent |
|
| T&P | Gas | Heating | Heating | Heater |
| Water | Shipping | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
Model | Gal. | Gal. |
| BTU | KW | Imp. | U.S. Liters/ | Conn. |
| Dia. |
| Size |
|
| Conn. | Conn. | Return | Outlet | Top |
| Conn. | Weight | |||||||||||
Number | Cap. | Cap. | Liters | Input | BTU | GPH | GPH | Hr | in. | mm | in. | mm |
| in. | mm |
| in. | mm | in. | mm | in. | mm | in. mm | in. mm | in. mm | lbs. kg | |||||||
48 | 182 | 65,000 | 19.1 | 52 | 63 | 238 | 631⁄4 | 1607 | 22 | 559 |
| 3 | 76 |
| 51 | 1295 | 161⁄2 | 419 | 141⁄2 368 | 51 1295 | 571⁄4 1454 | 58 | 1473 | 188 | 85 | ||||||||
54 | 65 | 246 | 65,000 | 19.1 | 52 | 63 | 238 | 663⁄4 | 1695 | 22 | 559 |
| 3 | 76 |
| 541⁄2 1384 | 161⁄2 419 | 141⁄2 368 | 541⁄2 1384 | 603⁄4 1543 | 611⁄2 | 1562 | 222 | 101 | |||||||||
62 | 75 | 284 | 76,000 | 22.3 | 61 | 74 | 276 | 66 |
| 1676 | 26 | 660 |
| 3 | 76 |
| 53 | 1346 | 183⁄4 | 476 | 173⁄4 | 451 | 53 1346 | 60 1524 | 603⁄4 | 1543 | 277 | 126 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
For LP Gas models, change suffix “B” to “X”. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
**Based on manufacturers rated recovery efficiency. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| (LP) Propane Gas Inputs |
|
|
|
|
|
|
| Recovery at 56°C Rise and 100°F Rise |
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
110 V.A.C. Required for Power Venting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Imp GPH | US GPH |
| Liters/Hr |
| ||||||||
|
|
|
|
|
|
| 18.5 KW | 63,000 BTU/Hr | 58 |
| 68 |
|
| 257 |
| ||||||||||||||||||
110 V.A.C. 60HRZ | 2.1 Amperes |
|
|
|
|
|
|
| 18.5 KW | 63,000 BTU/Hr | 58 |
| 68 |
|
| 257 |
| ||||||||||||||||
Water Connections are 3⁄4" (19mm) on 11" centers |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
MAXIMUM HORIZONTAL AND VERTICAL VENT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
3" PVC, ABS & CPVC (76mm) | 4" PVC, ABS & CPVC (102mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
30 ft. (9 m) |
|
| 60 ft. (18 m) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ambler, PA |
|
|
|
| |||||
|
| (3) 90° elbows |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Suitable for Water (Potable) Heating and Space Heating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| For U.S. and Canada field service, |
|
| |||||||||||||
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this |
|
|
|
|
|
| contact your professional installer or |
|
| ||||||||||||||||||||||||
system. This unit may NEVER be connected to any existing heating system or component(s) |
|
|
|
|
|
| local Bradford White sales representative. |
|
| ||||||||||||||||||||||||
previously used with a |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
|
|
| Technical |
| |||||||||||||||||||||||||||
ASHRAE Standard 90.1b (current standard). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI Working |
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||
pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 11" (279mm) centers, all gas |
|
|
|
|
|
| |||||||||||||||||||||||||||
connections 1⁄2" (13mm). All models design certified by CSA International (formerly AGA/CGA) |
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
and peak performance rated. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| International: |
|
|
|
| ||||
As an Automatic Storage Heater, all models are complete |
|
|
|
|
|
|
| ||||||||||||||||||||||||||
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||
It needs no separate storage tank, pump, wiring or elaborate piping network. These models can |
|
|
|
|
| Fax on Demand: |
|
|
|
| |||||||||||||||||||||||
be used either as a single unit or in multiples connected in parallel. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
Sample Specification |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| www.bradfordwhite.com |
|
| ||||||||
The water heater shall be a Bradford White model with a rated storage capacity of not less than |
|
|
|
|
|
| |||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
_______ gallons (liters), a minimum gas input of | __________ BTUH (KWH), and a minimum |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
recovery of _______ GPH (LPH) at 100°F (56°C) temperature rise. It shall be design certified by |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
CSA International (formerly AGA/CGA). The tank shall be lined with Vitraglas® vitreous enamel. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
The tank shall have one extruded magnesium anode rod. The heater shall be insulated with Non- |
|
|
|
|
|
| Mississauga, ON |
|
|
|
| ||||||||||||||||||||||
CFC foam insulation. This water heater shall be equipped with an ASME rated T&P relief valve, a |
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
factory installed blower assembly and electronic ignition system (110V AC required). The entire |
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||
installation shall be in compliance with state and local codes and ordinances |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
Dimensions and specifications subject to change without notice in accordance with our |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
policy of continuous product improvement. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Technical |
| ||||||||||||||
Hydrojet® and Vitraglas® are registered trademarks of Bradford White® Corporation. |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| www.bradfordwhitecanada.com |
| ||||||||||||||||||||||
©2004, Bradford White Corporation. All rights reserved. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ΠΡΟΔΥΧΤΣ ΟΝΛΨ ΦΟΡ ΠΡΟΦΕΣΣΙΟΝΑΛΣ |