Bradford-White Corp PE2XR504T*F(BN,SX), PE4503*F(BN,SX), PE440T*F(BN,SX) Specifications

Models: PE4403S*F(BN,SX) PE440T*F(BN,SX) PE4503*F(BN,SX) PE2XR504T*F(BN,SX)

1 32
Download 32 pages 33.66 Kb
Page 7
Image 7

Specifications

 

Specifications

 

 

Power Supply

Dedicated 120VAC, 60 Hz, 15A

 

 

Gas Supply Pipe

Minimum 1/2” NPT (Schedule 40 black iron pipe

recommended)

 

 

 

Approved Gas Type

Natural or Propane; unit must match gas type supplied

 

 

Gas Pressure

5” w.c. minimum for Natural Gas; 11” w.c. for Propane; 14”

w.c. maximum for Natural Gas / Propane

 

 

 

Approved Vent Materials

Single or Double Wall Metal Vent Pipe

 

 

Minimum Clearance for

18” from top; 24” from front; 4” from sides and rear

Servicing

 

 

 

Water Supply Pressure

150 psi maximum allowable working pressure; check local

codes for supply pressure

 

 

 

ECO Limit

188°F (87°C)

 

 

Temperature Setpoint Range

60°F (16°C) to 160°F (71°C); approximate temperatures

 

 