Gas Control Removal
Gas Control Removal From Thermal Well
Following the steps below allow for the removal of the gas control from the thermal well without removing the thermal well from the tank.
Step 1. Move the gas control power switch to the “OFF” position.
Gas control power
switch
Step 2. Unplug the water heater and Accessory Module from the wall outlet.
Water heater power cord and
Accessory Module transformer
Step 3. Turn off the gas supply to the water heater and disconnect the gas piping from the gas control.
Step 4. Disconnect the pilot tube using a 7/16” wrench and the main burner feedline with a 3/4” wrench from the gas control.
Pilot and main
feedlines
Step 5. Disconnect the wire harnesses and spark igniter/ flame sense wire from the gas control.
Gas control
Spark igniter/flame
sensor wire
Step 6. Using the gas control service tool, p/n
Gas control service
tool