Bradford-White Corp Powered Direct Vent Series instruction manual Reduce 10.1 cm to 7.6 cm

Models: Powered Direct Vent Series

1 43
Download 43 pages 7.39 Kb
Page 19
Image 19
(Reduce 10.1 cm to 7.6 cm)

Venting continued-

TABLE 4

3” (7.6 cm) PVC VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR

LOW GROUND CLEARANCE INSTALLATIONS

Terminating

# of Elbows

Maximum # of

 

(intake + exhaust)

Feet of Straight

 

 

Pipe

 

 

(intake + exhaust)

(2) 90° Elbows with (1) 90°

2

50 ft (15.2 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

3

45 ft (13.7 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

4

40 ft (12.2 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

5

35 ft (10.7 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

6

30 ft (9.1 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

7

25 ft (7.6 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

8

20 ft (6.1 m)

Elbow

 

 

TABLE 5

4” (10.1 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR

LOW GROUND CLEARANCE INSTALLATIONS

Terminating (Reduce 4” to 3”)

#of Elbows

Maximum # of

(Reduce 10.1 cm to 7.6 cm)

(intake + exhaust)

Feet of Straight

 

 

Pipe

 

 

(intake + exhaust)

(2) 90° Elbows with (1) 90°

2

120 ft (36.6 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

3

115 ft (35.1 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

4

110 ft (33.5 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

5

105 ft (32.0 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

6

100 ft (30.5 m)

Elbow

 

 

(2) 90° Elbows with (1) 90°

7

95 ft (29.0 m)

Elbow

 

 

 

19

 