SERVICE PROCEDURE MCE-VIHigh Limit (ECO) TestingPage 20
High Limit Control (ECO) Testing for
Contactor Models
1. Determine if Hi-Limit has actuated. This can be done by simply
depressing the reset buttons. If you hear and/or feel
a small click, the switch has actuated.
2. Use caution and turn power on to water heater and observe
heating cycle following the Hi-Limit Heating Cycle flow chart.
Switch Contacts:
Normally closed.
Open on rise @ 196°F ±4°F
Manual Reset.
DANGER
High voltage exposure. To avoidhazard to Life or prope rty, be surepower is turned OFF to water heaterwhile performing this procedure.
NIs water temp
over 196°F
N
Observe heating cycle.
Does switch open?
Switch OK
Is water temp
over 196°F
Replace switch
N
Y
Y
1. STOP, DANGER! Turn power “OFF” to water heater.
2. Water temperature must be below 196°F ±4°F
3. Remove Hi-Limit switch from control panel. It is not necessary
to remove immersion bulb from tank at this time. See
general controls layout on page 4 for location.
4. Disconnect wire leads to Hi-Limit Control during this test.
5. Depress reset buttons to insure switch contacts are closed.
6. Set multi-meter to Ohms setting, Check continuity Thru circuit A & B as shown in the illustrations below.
- Continuity IS present, Switch is okay.
- Continuity NOT present, Replace switch.
High Limit Control Contin uity Testing for
Contactor Models
High Limit Heating Cycle Flow Chart
NOTE
Disconnect
Wire Leads to Control
Circuit “A” Continuity Testing Circuit “B” Continuity Testing
Y
20