SERVICE PROCEDURE MCE-XIThermostat Removal and Replacement
Front View
Thermostat Mounting
Surface Mounted Thermostat Removal
1. STOP, DANGER! Turn power “OFF” to water heater.
2. Remove access cover from lower control box.
Remove insulation from inside of control box.
Remove plastic cover from thermostat.
3. Disconnect wires from thermostat terminals. It may be necessary to label wi resf orp roper re-connection to
new thermostat.
4. Note thermostat temperature setting for proper setting of new thermos tat.
5. Slide thermostat upwards and out of mounting bracket.
Surface Mounted Thermostat Replacement
1. Use a stiff brush to remove a ny debris or loose scale from tank surfac e where new thermostat will be installed.
2. Slide new thermostat down into thermostat bracket until it snaps into plac e. IMPORTANT! Thermostat must set
completely flat or flush to tank surface. An improperly installed thermostat will cause improp erwat er heater
operation.
3. Refer to the wire diagram loc ated on the inside of the upper control box cover and re-connect wires to the thermostat.
Be sure wire connections are snug and corrosion free. Do not over tighten, doin g somay d amage thermostat.
4. Set thermostat to the original thermostat setting found on the old thermost at.
5. Restore power to water heater and verify proper
heater operation.
Thermostat
Thermostat
mounting
bracket
Side View
ProperThermostat
Mounting
Tank Surface
Side View
Improper Thermostat
Mounting
Proper Thermostat mounting
flush with tank surface
Improper Thermostat mo unting.
Thermostatnot flush with tanksurface
Page 26
DANGER
High voltage exposure. To avoid hazard to
Life or property, be sure power is turned OFFto water heater while performing this
procedure.
26