Bradley Smoker MG-2/TT Hot Cold Supplies, Single Tempered Supply, Connecting supply

Models: MG-2/TT

1 20
Download 20 pages 13.09 Kb
Page 10
Image 10

Express® Lavatory System - MG-Series with TouchTime® Control

 

MG-2/TT

Installation Instructions

Installation Instructions continued . . .

Step 5: Connecting supply

1.Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see Figure 5b). Then lift up to remove the valve bracket from the frame.

2FOR HOT AND COLD SUPPLY: Attach the stop/check to the hot and cold water supply piping from the wall. Connect the flexible hoses to the Vernatherm™ Mixing Valve and to the check/stops (see Figure 5a).

NOTE: The “H” on Vernatherm™ Mixing Valve indicates hot water supply inlet.

FOR SINGLE TEMPERED SUPPLY: Attach the stop/check to the 1/2" tempered supply line. Connect the stop/check to the tempered line adapter with the flexible supply hose (Figure 5c).

3.Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2" drain pipe stubbed out of the wall.

4.Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly into place. Secure the stainer with the screw provided.

Hot and

Cold

Supplies

VERNATHERM™ THERMOSTATIC

MIXING VALVE

FLEXIBLE SUPPLY

HOSE

Figure 5a

FLEXIBLE

SUPPLY

HOSE

CONNECT TO 1/2" NPT HOT WATER SUPPLY

CONNECT TO 1/2" NPT COLD WATER SUPPLY

VALVE BRACKET

MOUNTING SCREW

SLOT IN

FRAME

Figure 5b

Single

Tempered

Supply

Figure 5c

FLEXIBLE SUPPLY HOSE (TO SOLENOID BRACKET)

TEMPERED

TO SUPPLY LINE

 

LINE ADAPTER

 

(S39-685)

 

10

2/8/07

Bradley Corporation • 215-1480 Rev. E; EN 06-915

Page 10
Image 10
Bradley Smoker MG-2/TT installation instructions Hot Cold Supplies, Single Tempered Supply, Connecting supply