Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 31312
-ANUAL /PERATING )NSTRUCTIONS
%LECTRICAL /VERRIDEL)NSTRUCTIONS
WARNING |
|
| If you experience power or equipment | Hand Crank Note: |
| |
|
| failure, refer to the Manual Operating |
| |||
Do not use electrical |
|
| Instructions to operate the lift. Do not | For easier operation |
| |
|
| use electrical override to operate lift |
| |||
|
| of the hand crank, |
| |||
override to operate |
|
| when a passenger is on the platform. | press and hold the |
| |
lift when a passenger |
|
|
| |||
|
|
|
| electrical override |
| |
is on the platform. |
|
| Refer to the Lift Operating Instructions |
| ||
|
| MANUAL/BRAKE |
| |||
Doing so may result |
|
|
| |||
|
| for all normal lift operation procedures | RELEASE switch in |
| ||
in serious bodily |
|
|
| |||
|
| (such as loading and unloading pas- | the MANUAL position |
| ||
injury and/or property |
|
|
| |||
|
| sengers). Follow all Lift Operation | while turning crank. |
| ||
damage. |
|
|
| |||
|
| Safety Precautions! |
|
|
| |
|
|
|
|
|
| |
PLATFORM LATCH |
|
| INBOARD LOCATOR | ACTUATOR | MOTOR |
|
Locked |
|
| Hairpin | Cap | Plug |
|
|
|
|
|
|
| |
I |
|
|
| Stow | Deploy Down | Up |
|
|
|
|
|
| |
n |
|
|
|
|
| |
b |
|
|
|
| ||
L | o |
|
|
|
| |
| ar |
|
|
| ||
o |
| d |
|
|
| |
| c |
|
|
|
| |
| at |
|
|
| ||
Unlocked |
|
| or |
|
|
|
|
|
|
|
|
| |
|
|
| Link |
|
|
|
The Electrical Override feature is provided as a diagnostic procedure to reset the system and as an alternative method of operating the lift without a
WARNING
•Do not use electrical override to operate lift when a passenger is on the platform.
•Override switches must be released to stop lift at desired
position.
Failure to follow these rules may result in serious bodily injury and/or property dam- age.
passenger only. Do not use the electrical override to oper- ate the lift when a passenger is on the platform. Lift functions operate at higher rate of speed when using the electrical over- ride. When using the electrical override, the operator must stop pressing the applicable override switch when the lift reaches the desired position (limit switches
Locked
Unlocked
&IGUREE!
will not function).
Note: Following electrical override procedures, press the two override rocker switches to NORMAL. Close access cover and press the main control switch to STOW. Function lift through one full cycle to ensure proper operation.
Electrical Override Switches
&IGUREE! |
| &IGUREE" |
| &IGUREE# |
| &IGUREE$ |
TO OPEN DOOR(S):
Manually open door(s) fully and secure.
TO OPEN DOOR(S):
Manually open door(s) fully and secure.
TO OPEN DOOR(S):
Manually open door(s) fully and secure.
TO DEPLOY PLATFORM:
1.Unlock (disengage) latch under middle platform section. See Figure A.
2.Manually open (rotate) the three platform sections to full width.
3.Engage latch under middle platform section to lock plat- form sections at full width. See Figure A.
4.Remove cap from top of verti- cal arm actuator. See Figure C.
5.Place crank handle on actuator shaft and turn counterclock- wise until platform reaches
floor level. See Figure C.
Remove crank handle.
TO DEPLOY INBOARD
LOCATOR:
1.Remove hairpin cotter from inboard locator link pin. See Figure B.
2.Remove link from inboard loca- tor pin. See Figure B.
3.Lower (unfold) inboard locator to vehicle floor.
TO STOW INBOARD LOCATOR:
1.Raise (fold) inboard locator to vertical position.
2.Place link on inboard locator pin. See Figure B.
3.Insert hairpin cotter into inboard locator link pin. See Figure B.
TO LOWER PLATFORM:
1.Remove plug from top of motor cover. See Figure D.
2.Place crank handle on motor shaft and turn clockwise until platform reaches ground level. See Figure D. Remove crank handle.
TO RAISE PLATFORM:
1.Remove plug from top of motor cover. See Figure D.
2.Place crank handle on motor shaft and turn counterclockwise until platform reaches floor level. See Figure D. Remove crank handle.
TO STOW PLATFORM:
1.Remove cap from top of vertical arm actuator. See Figure C.
2.Place crank handle on actuator shaft and turn clockwise until platform stops (reaches full vertical position). See Figure C. Remove crank handle.
3.Unlock (disengage) latch under middle platform section. See Figure A.
4.Manually close (rotate) the three platform sections
5.Engage latch under middle platform section to lock platform sections. See Figure A.
TO CLOSE DOOR(S):
Manually close door(s).
TO DEPLOY PLATFORM:
1.Unlock (disengage) latch under middle platform section. See Figure A.
2.Manually open (rotate) the three platform sec- tions to full width (unfolded).
3.Engage latch under middle platform section to lock platform sections at full width. See Figure A.
4.Rotate the access cover to expose the override switches. See above photo.
5.Press the two override rocker switches to
OVERRIDE.
6.Press the left toggle switch to DEPLOY until platform reaches floor level. Release switch.
7.Press the right toggle switch to DOWN until platform reaches ground level. Release switch.
8.To deploy (unfold) the outer barrier, press the left toggle switch to DEPLOY until barrier unfolds fully. Release switch.
TO STOW PLATFORM:
1.Rotate the access cover to expose the override switches. See above photo.
2.Press the two override rocker switches to
OVERRIDE.
3.To raise (fold) the outer barrier to vertical posi- tion, press the left toggle switch to STOW until barrier folds fully. Release switch.
4.Press the right toggle switch to UP until plat- form reaches floor level. Release switch.
5.Press the left toggle switch to STOW until plat- form reaches vertical position. Release switch.
6.Unlock (disengage) latch under middle platform section. See Figure A.
7.Manually close (rotate) the three platform sec- tions to closed position (folded).
8.Engage latch under middle platform section to lock platform sections. See Figure A.