Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32553 Rev. A
4 | Door Operators/Switch, Terminal |
5 | FMVSS 403/404 Certification Checklist |
Strip and Floor Level Adjustment |
Visual and Audible Threshold Warning
DOT — Public Use Lift
Terminal Strip
Power Door Operators
Public use vehicle manufacturers are responsible for complying with the lift lighting requirements in Fed-
The
Black
Jumper
1 2 3 4 5 6 7 8 9 10
Figure O
Install optional power door oper- ators as detailed in the instructions supplied with door operator kit.
Route the wires to the pump mod- ule and connect to the terminal strip as shown in Figure P.
To Door Openers
“Open” Trigger
Door Cutout
Door Cutout
To Door Openers “Close” Trigger
Orange
Black
Red
Blue
1 2 3 4 5 6 7 8 9 10
Figure P
C_SW
O_RL
N/C
IN_LK
12_V
PWR
GND
F_LV
O_SW
C_RL
Platform
Lighting
Threshold
Area
ld ThreshosorMat Sen
eral Motor Vehicle Safety Standard No. 404, Platform Lift Installation in Motor Vehicles (49 CFR 571.404).
Inner
Roll Stop
Floor Level and Inner Roll Stop Adjustments
Achieving proper floor level positioning of the platform and inner roll stop requires a combina- tion of Floor Level switch adjustment and inner roll stop adjustment. Both are factory set but must be inspected during installation procedures (will vary per vehicle application).
Ensure the lift is positioned and secured as speci- fied above (panels 1 and 2). Adjust the Floor Level switch first (detailed below). Then, adjust the inner roll stop as detailed in the service manual (adjust only if necessary). The inner roll stop must rest properly on the vehicle floor for wheelchair entry and exit.
JKA
Dual
Outer Barrier
Platform
Floor Level Switch
Floor Level Cam | Floor Level Switch |
The Floor Level switch stops upward travel of the platform during the Up function (activated by the torque
Note: Check the floor level position of the plat- |
|
|
form and the inner roll stop after powering the |
|
|
pump. Hydraulic pressure may affect platform |
|
|
height slightly. Fine tuning adjustment (tweak- |
|
|
ing) of the Floor Level switch may be required. | Torque Tube | Cam depressing switch. |
The operations listed below must be functionally verified.
Vehicle movement is prevented unless the lift
door is closed, ensuring the lift is stowed.
Lift operation shall be prevented unless the vehicle is stopped and vehicle movement is prevented.
The platform will not fold/stow if occupied.
The outer barrier will not raise if occupied.
The inner roll stop will not raise if occupied.
Platform movement is prohibited beyond the position where the inner roll stop is fully deployed (up).
A visual and audible warning will activate if the threshold area is occupied when the plat- form is at least one inch below floor level.
Lift platform movement shall be interrupted unless the outer barrier is deployed (up).