Breckwell P24I Thermostat Installation, Optional Thermostat, A Millivolt Thermostat Is Required

Models: P24FS P24I

1 32
Download 32 pages 4.64 Kb
Page 18
Image 18
THERMOSTAT INSTALLATION

18

THERMOSTAT INSTALLATION

OPTIONAL THERMOSTAT

A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fixed wall mount or Breckwell’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat mode.

THERMOSTAT INSTALLATION

A MILLIVOLT THERMOSTAT IS REQUIRED.

Unplug stove from power outlet.

Remove control board from stove.

The two thermostat wires connect to the terminal block on the lower left side of the back of the control board.

(See figure 21)

Insert the wires in the terminal side and tighten the two screws.

MODES

TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE

MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE

STOVE RESTARTED.

MANUAL MODE

In this mode the stove will operate only from the control panel as detailed in the “OPERATION” section of this owner’s manual.

HIGH/LOW THERMOSTAT MODE

When engaged in this mode the stove will automatically switch between two settings. When warm enough, it will switch to the #1 or low setting. The room air blower will also slow to its lowest speed.

The Heat Level Advance setting on the bar graph will stay where it was initially set. When the house cools below the thermostat setting, the stove will switch to the feed rate of the heat level advance setting.

ON/OFF THERMOSTAT MODE

In this mode when the home is warm enough the stove will shut off. The fans will continue to run until the stove cools.

When the home cools below the thermostat setting, the stove will automatically restart and run at the last feed rate setting.

NOTE: When in “high/low” or “on/off” thermostat mode –

Do not operate the stove higher than the #3 setting.

Set damper control rod approximately ½” to ¾” out. This will vary depending on elevation and weather conditions. Observe stoves operation and adjust damper as necessary.

FIGURE 14

Page 18
Image 18
Breckwell P24I, P24FS owner manual Thermostat Installation, Optional Thermostat, A Millivolt Thermostat Is Required, Modes