20

TROUBLESHOOTING GUIDE

STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES

Possible Causes:

Possible Remedies: (Unplug stove first when possible)

 

 

 

1.

The hopper is out of pellets.

Refill the hopper.

 

 

 

2.

The air damper is too far open for a low feed setting.

If burning on the low setting, you may need to close the damper all

 

 

the way (push the knob in so it touches the side of the stove).

 

 

 

3.

The burnpot is not pushed completely to the rear of the firebox.

Make sure that the air intake collar on the burnpot is touching the

 

 

rear wall of the firebox.

 

 

 

4.

The burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

 

 

 

5.

The air inlet, the interior chambers, or exhaust system has a

Follow all cleaning procedures in the maintenance section of the

 

partial blockage.

owner’s manual.

 

 

 

6.

The auger shaft is jammed.

Start by emptying the hopper. Then remove the auger motor by

 

 

removing the auger pin. Remove the auger shaft inspection plate in

 

 

the hopper so that you can see the auger shaft. Gently lift the auger

 

 

shaft straight up so that the end of the auger shaft comes up out of

 

 

the bottom auger bushing. Next, remove the two nuts that hold the

 

 

top auger biscuit in. Then rotate the bottom end of the auger shaft

 

 

up towards you until you can lift the shaft out of the stove. After you

 

 

have removed the shaft, inspect it for bent flights, burrs, or broken

 

 

welds. Remove any foreign material that might have caused the

 

 

jam. Also, check the auger tube for signs of damage such as burrs,

 

 

rough spots, or grooves cut into the metal that could have caused a

 

 

jam.

 

 

 

7.

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the unit.

 

 

If the motor will turn the shaft is jammed on something. If the motor

 

 

will not turn, the motor is bad.

 

 

 

8.

The Proof of Fire (POF) thermodisc has malfunctioned.

Temporarily bypass the POF thermodisc by disconnecting the two

 

 

brown wires and connecting them with a short piece of wire. Then

 

 

plug the stove back in. If the stove comes on and works, you need

 

 

to replace the POF thermodisc. This is for testing only. DO NOT

 

 

LEAVE THE THERMODISC BYPASSED. Your blowers will never

 

 

shut off and if the fire went out the auger will continue to feed pellets

 

 

until the hopper is empty if you leave the POF thermodisc bypassed.

 

 

 

9.

The high limit thermodisc has tripped or is defective.

Wait for the stove to cool for about 30 - 45 minutes. It should now

 

 

function normally. If not use the owner’s manual to locate the high

 

 

limit thermodisk. To test if the thermodisk is bad, you can bypass it

 

 

as described previously for the POF thermodisk.

 

 

 

10.

The fuse on the control board has blown.

Remove the control board. If the fuse appears to be bad, replace it

 

 

with a 5 Amp 250 Volt fuse. Plug the stove back in and try to run the

 

 

unit.

 

 

11. The control board is not sending power to the POF thermodisc

There should be a 5-volt (approximately) current going to the POF

 

or other auger system components.

thermodisc after the stove has been on for 10 minutes.

 

 

 

Page 20
Image 20
Breckwell P4000 owner manual Stove Shuts OFF and the # 3 Light Flashes

P4000 specifications

The Breckwell P4000 is a pellet stove that combines efficiency, performance, and stylish design, making it an ideal choice for homeowners seeking an eco-friendly heating solution. With its robust construction and advanced technology, the P4000 stands out in a crowded market of heating appliances.

One of the key features of the Breckwell P4000 is its high heating capacity. Designed to heat spaces up to 2,200 square feet, it has a maximum output of 40,000 BTUs. This makes it suitable for both small and large rooms, providing a comfortable environment even in the coldest months. The stove also includes a large hopper capacity, able to hold up to 60 pounds of pellets, allowing for longer burn times without the need for constant refueling.

The P4000 is equipped with an advanced digital control panel. This user-friendly interface allows homeowners to easily adjust the thermostat and control the flame intensity, ensuring an optimal heating experience. Additionally, it features an automatic igniter for hassle-free start-up, allowing users to ignite their stove with the push of a button.

Efficiency and environmental performance are cornerstones of the Breckwell P4000's design. The stove boasts an impressive efficiency rating of up to 87%, meaning that minimal heat is lost during operation. This efficiency not only leads to lower heating bills but also reduces the environmental impact, as pellet stoves are considered a renewable energy source.

The P4000 also emphasizes safety, featuring a list of safety controls including a heat sensor and an automatic shut-off function. This ensures peace of mind for users, as it reduces the risk of overheating or fire hazards.

Another appealing aspect of the Breckwell P4000 is its aesthetic versatility. The stove comes in various finishes, including traditional black and modern stainless steel, allowing it to seamlessly integrate into various home decors. Its compact design ensures it can fit into tight spaces while still delivering powerful heating performance.

In conclusion, the Breckwell P4000 pellet stove combines modern technology, high efficiency, and attractive design. Its powerful heating capabilities, user-friendly controls, and safety features make it an excellent choice for homeowners looking for a reliable and stylish heating solution. Whether for a cozy living room or an expansive open space, the P4000 is dedicated to providing warmth and comfort during the cold months.