Figure 17 - Changing Pump Oil

Oil Cap

3.Tilt pressure washer to drain oil into an approved container until it drips slowly from pump.

2.Shut off engine and let it cool, then remove high pressure and garden hoses. Disconnect spark plug wire from spark plug.

3.Place the spray gun, nozzle extension, floor brush, utility brush, brush extension and high pressure hose in the accessory storage bag.

4.Empty pump of all pumped liquids by pulling recoil handle about 6 times.This should remove most liquid in pump.

5.Use PumpSaver to prevent corrosion build up and freezing of pump.

6.Store unit in a clean, dry area.

4.Tilt pressure washer in opposite direction and empty premeasured pump oil bottle into same opening (a small funnel may be helpful).

5.Install black pump oil cap and tighten firmly.

6.Set pressure washer in upright position. Add fuel and engine oil.

ENGINE MAINTENANCE

See the engine owner’s manual for instructions on how to properly maintain the engine.

Protecting the Pump

To protect the pump from damage caused by mineral deposits or freezing, use PumpSaver to treat pump.This prevents freeze damage and lubricates pistons and seals.

CAUTION

You must protect your unit from freezing temperatures.

Failure to do so will permanently damage your pump and render your unit inoperable.

Freeze damage is not covered under warranty.

Protecting the Pump CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

PREPARING THE UNIT FOR STORAGE

Water should not remain in the unit for long periods of time. Sediments or minerals can deposit on pump parts and “freeze” pump action. If you do not plan to use the pressure washer for more than 30 days, follow this procedure:

1.Flush chemical injection hose by placing filter into a pail of clean water while running pressure washer in low pressure mode (adjustable nozzle in forward position). Flush for one to two minutes.

PREPARING THE UNIT FOR STORAGE CAUTION

Read and follow all cautions and warnings on the PumpSaver can label.

• Always wear eye protection when using PumpSaver.

NOTE: PumpSaver is available as an optional accessory. It is not included with the pressure washer. Contact the nearest authorized service center to purchase PumpSaver.

To use PumpSaver, make sure the pressure washer is turned off and disconnected from supply water. Read and follow all instructions and warnings given on the PumpSaver container.

NOTE: PumpSaver will drip from pump after treatment and will stain wood and concrete.

NOTE: If PumpSaver is not available, draw RV antifreeze (non-alcohol) into the pump by pouring the solution into a 3-foot section of garden hose connected to inlet adapter and pulling recoil handle twice.

STORING THE ENGINE