USING THE GENERATOR

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).

Special Requirements

There may be National regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s

Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Generator Clearance

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

The generator must be at least 2m (5 ft.) from structures having combustible walls and/or other combustible materials. Leave at least 1m (3 ft.) all around generator including overhead, for adequate cooling, maintenance and servicing.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 3). Prevailing winds and air currents should be taken into consideration when positioning generator.

Figure 3 — Generator Clearance

Typical Generator Shown

Exhaust Port

8

Page 8
Image 8
Briggs & Stratton 030213, 030212 Using the Generator, System Ground, Connecting to a Building’s Electrical System

030212, 030213 specifications

Briggs & Stratton is a well-known name in the realm of small engines, particularly for outdoor power equipment. The models 030212 and 030213 showcase the company’s commitment to quality, innovation, and performance. These engines are primarily designed for residential and commercial applications, offering reliability and efficiency for various power equipment needs.

The Briggs & Stratton 030212 and 030213 engines are distinguished by their robust construction and advanced engineering. One of the notable features is their overhead valve (OHV) design, which enhances airflow and fuel efficiency. This design not only results in lower emissions but also delivers better torque and power during operation. As a result, users can expect higher performance from these engines, making them ideal for lawn mowers, generators, pressure washers, and other outdoor equipment.

Both models come equipped with a reliable recoil start system, ensuring that starting the engine is user-friendly and straightforward. In terms of maintenance, Briggs & Stratton has integrated a simple oil check and fill system, allowing operators to easily monitor and maintain oil levels to optimize engine performance and longevity.

Another standout characteristic of these engines is their enhanced fuel efficiency. By incorporating state-of-the-art fuel management technology, the 030212 and 030213 minimize fuel consumption while maximizing output. This not only translates to cost savings for users but also contributes to environmentally friendly operation.

The engines also feature a dual-air cleaner system. This system helps ensure clean air intake, reducing dust and debris that can impact engine performance. The enhanced filtration contributes to longer engine life and decreased maintenance intervals, allowing users to focus on their tasks rather than frequent engine upkeep.

Furthermore, the engines boast a compact and lightweight design, which makes them easy to install and transport. This portability is a significant advantage for those who use them across multiple locations or in varied applications.

Overall, the Briggs & Stratton 030212 and 030213 engines exemplify the company’s dedication to innovation and performance. With their advanced features, user-friendly design, and efficiency-conscious engineering, these models serve as reliable power sources for a range of outdoor and utility applications, solidifying Briggs & Stratton's reputation in the small engine market.