6200W Portable Generator

OPERATING THE

GENERATOR

Starting the Engine

IMPORTANT: Always unplug the battery float charger before starting the generator.

Disconnect all electrical loads from the generator. Use the following start instructions:

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or to shut down during operation.

2.Turn the fuel valve to the “On” position (Figure 5). The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

Figure 5 — Fuel Valve

Fuel Valve is shown in the On position

3.Start engine according to instructions given in the engine operator’s manual.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit may be equipped with a low oil protection device. See engine operator’s manual.

WARNING

Running engines produce heat. Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.

DO NOT connect 3–phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload the Generator”.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

11

Page 11
Image 11
Briggs & Stratton 030242 manual Operating Generator, Starting the Engine, Connecting Electrical Loads

030242 specifications

The Briggs & Stratton 030242 is a powerful and reliable portable generator that caters to a wide range of power needs. Renowned for its performance and durability, this generator is an ideal choice for homeowners seeking backup power solutions during outages, as well as for outdoor enthusiasts who require dependable energy sources for camping or recreational activities.

One of the standout features of the Briggs & Stratton 030242 is its impressive power output. It boasts a starting wattage of 3,000 watts and a running wattage of 2,500 watts, making it capable of supporting essential household appliances like refrigerators, lights, and sump pumps. This makes it particularly useful during power outages or in emergency situations. The generator is powered by a reliable 206cc OHV engine, designed for easy starting and efficient fuel consumption, allowing users to maximize their usage time before refueling is necessary.

The 030242 integrates advanced technology, including a low-oil shutdown feature that protects the engine from damage by automatically turning off the generator when oil levels are low. This assures users that they can operate the generator without the constant worry of monitoring oil levels. The generator is also equipped with a built-in surge protector, which helps safeguard connected devices from power spikes, ensuring they remain safe and functional.

Portability is another key characteristic of the Briggs & Stratton 030242. It features a lightweight design and includes convenient fold-down handles, allowing for easy mobility. With sturdy wheels, it can be effortlessly transported to various locations, whether it’s in the backyard or out in the field.

The generator features multiple outlets, including two 120V household outlets and one 12V DC outlet for charging batteries, expanding its versatility in powering various tools and devices. Additionally, the noise level is kept to a minimum, producing only 59 dB at 25% load, which is quieter than many traditional generators, making it more pleasant for users and their neighbors.

In summary, the Briggs & Stratton 030242 is a versatile and efficient generator that combines power, portability, and advanced safety features, making it an excellent investment for anyone in need of reliable energy solutions.