SPECIFICATIONS

Starting Wattage . . . . . . . . . . . . . . . . . .8,750 watts Wattage . . . . . . . . . . . . . . . . . . . . . . . . .6,200 watts AC Load Current:

At 120 Volts . . . . . . . . . . . . . . . . . . . . .51.6 Amps At 240 Volts . . . . . . . . . . . . . . . . . . . .25.8 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase Rated Frequency . . . . . . . . . . . . . . . . . . . .60 Hertz Fuel Tank Capacity. . . . . . . . . . . . . . . 7 U.S. gallons Shipping Weight. . . . . . . . . . . . . . . . . . . . . . 198 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER

operate a damaged or defective generator.

NOTE: Should you have questions about replacing components on your BSPP generator, please call 1-800-743-4115for assistance.

Engine Maintenance

See engine operator’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN.

DON'T POLLUTE. CONSERVE

RESOURCES. RETURN USED OIL TO

COLLECTION CENTERS.

6200W Portable Generator

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Inspect cooling air slots and opening on generator. These openings must be kept clean and unobstructed.

14

Page 14
Image 14
Briggs & Stratton 030242 manual Specifications, General Maintenance Recommendations

030242 specifications

The Briggs & Stratton 030242 is a powerful and reliable portable generator that caters to a wide range of power needs. Renowned for its performance and durability, this generator is an ideal choice for homeowners seeking backup power solutions during outages, as well as for outdoor enthusiasts who require dependable energy sources for camping or recreational activities.

One of the standout features of the Briggs & Stratton 030242 is its impressive power output. It boasts a starting wattage of 3,000 watts and a running wattage of 2,500 watts, making it capable of supporting essential household appliances like refrigerators, lights, and sump pumps. This makes it particularly useful during power outages or in emergency situations. The generator is powered by a reliable 206cc OHV engine, designed for easy starting and efficient fuel consumption, allowing users to maximize their usage time before refueling is necessary.

The 030242 integrates advanced technology, including a low-oil shutdown feature that protects the engine from damage by automatically turning off the generator when oil levels are low. This assures users that they can operate the generator without the constant worry of monitoring oil levels. The generator is also equipped with a built-in surge protector, which helps safeguard connected devices from power spikes, ensuring they remain safe and functional.

Portability is another key characteristic of the Briggs & Stratton 030242. It features a lightweight design and includes convenient fold-down handles, allowing for easy mobility. With sturdy wheels, it can be effortlessly transported to various locations, whether it’s in the backyard or out in the field.

The generator features multiple outlets, including two 120V household outlets and one 12V DC outlet for charging batteries, expanding its versatility in powering various tools and devices. Additionally, the noise level is kept to a minimum, producing only 59 dB at 25% load, which is quieter than many traditional generators, making it more pleasant for users and their neighbors.

In summary, the Briggs & Stratton 030242 is a versatile and efficient generator that combines power, portability, and advanced safety features, making it an excellent investment for anyone in need of reliable energy solutions.