6200W Portable Generator

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Generator Clearance

WARNING

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 4). Prevailing winds and air currents should be taken into consideration when positioning generator.

Using a generator indoors WILL KILL YOU IN MINUTES.

Exhaust contains carbon monoxide, a poison gas you cannot see or smell.

NEVER use in the home ONLY use outdoors and

or in partly enclosed far from open windows, areas such as garages. doors, and vents.

Figure 4 — Generator Clearance

Typical Generator Shown

Exhaust Port

10

Page 10
Image 10
Briggs & Stratton 030242 manual Using the Generator, System Ground, Connecting to a Building’s Electrical System

030242 specifications

The Briggs & Stratton 030242 is a powerful and reliable portable generator that caters to a wide range of power needs. Renowned for its performance and durability, this generator is an ideal choice for homeowners seeking backup power solutions during outages, as well as for outdoor enthusiasts who require dependable energy sources for camping or recreational activities.

One of the standout features of the Briggs & Stratton 030242 is its impressive power output. It boasts a starting wattage of 3,000 watts and a running wattage of 2,500 watts, making it capable of supporting essential household appliances like refrigerators, lights, and sump pumps. This makes it particularly useful during power outages or in emergency situations. The generator is powered by a reliable 206cc OHV engine, designed for easy starting and efficient fuel consumption, allowing users to maximize their usage time before refueling is necessary.

The 030242 integrates advanced technology, including a low-oil shutdown feature that protects the engine from damage by automatically turning off the generator when oil levels are low. This assures users that they can operate the generator without the constant worry of monitoring oil levels. The generator is also equipped with a built-in surge protector, which helps safeguard connected devices from power spikes, ensuring they remain safe and functional.

Portability is another key characteristic of the Briggs & Stratton 030242. It features a lightweight design and includes convenient fold-down handles, allowing for easy mobility. With sturdy wheels, it can be effortlessly transported to various locations, whether it’s in the backyard or out in the field.

The generator features multiple outlets, including two 120V household outlets and one 12V DC outlet for charging batteries, expanding its versatility in powering various tools and devices. Additionally, the noise level is kept to a minimum, producing only 59 dB at 25% load, which is quieter than many traditional generators, making it more pleasant for users and their neighbors.

In summary, the Briggs & Stratton 030242 is a versatile and efficient generator that combines power, portability, and advanced safety features, making it an excellent investment for anyone in need of reliable energy solutions.