PowerBOSS™

7000W Portable Generator

SAFETY RULES

 

 

 

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

Page 4
Image 4
Briggs & Stratton 30220 When Adjusting or Making Repairs to Your Generator, When Testing for Engine Spark

30220 specifications

The Briggs & Stratton 30220 is a powerful and versatile portable generator that has gained popularity among both residential and commercial users. Engineered for reliable performance, this generator is equipped with a range of features and technologies that make it an ideal choice for emergency backup power, recreational activities, and job site use.

One of the standout features of the Briggs & Stratton 30220 is its robust engine. Powered by a 306cc OHV (overhead valve) engine, it delivers a maximum output of 7,000 watts and a running wattage of 5,500 watts. This combination provides ample power for essential household appliances during power outages, as well as tools and equipment for construction or outdoor projects.

The 30220 model incorporates a durable steel frame, ensuring long-lasting durability and stability. Its design includes a user-friendly control panel for easy access to multiple power outlets, including four 120V household outlets and a 120V/240V twist-lock outlet. This versatility allows users to power everything from small appliances to larger equipment effortlessly.

One notable technological advancement in the Briggs & Stratton 30220 is the inclusion of EZ Start technology. This innovative feature simplifies the starting process, allowing users to start the generator smoothly with less effort. Additionally, the generator is equipped with a low-oil shutdown system that automatically turns off the engine to prevent damage, enhancing both safety and reliability.

Another key characteristic of the Briggs & Stratton 30220 is its fuel efficiency. The generator runs on gasoline, and with a 4-gallon fuel tank, it can provide up to 10 hours of continuous operation at a 50% load. This extended runtime makes it suitable for prolonged usage, such as during severe weather events.

Additionally, the generator is designed with mobility in mind. It features heavy-duty wheels and a fold-down handle for easy transportation, making it convenient to move wherever power is needed.

Overall, the Briggs & Stratton 30220 combines robust power, advanced technology, and user-friendly features, making it an exceptional choice for those in need of dependable and efficient portable power solutions. Whether for home use or outdoor adventures, this generator is built to deliver reliability and performance when it matters most.