OPERATION

OPERATING THE

GENERATOR

Starting the Engine

Disconnect all electrical loads from the generator. Follow these start instruction steps in numerical order:

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation.

2.Make sure the fuel line quick connect is hooked up and that all four tank hold-downs are firmly tight.

3.Turn the vent knob fully counter-clockwise. See Figure 4 on page 7.

4.Rotate the fuel valve to the “On” position. See Figure 5 on page 7.

5.Start the engine according to instructions given in the engine operator’s manual.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.

This unit may be equipped with a low oil protection device. See engine operator’s manual.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.

DO NOT connect 3–phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload Generator”.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

10

Page 10
Image 10
Briggs & Stratton 30253 manuel dutilisation Operating Generator, Starting the Engine, Connecting Electrical Loads

30253 specifications

Briggs & Stratton 30253 is a powerful and versatile portable generator designed to meet the needs of both homeowners and outdoor enthusiasts. Renowned for its reliability and efficient performance, this generator provides a dependable source of power during emergencies, outdoor events, or for recreational activities.

One of the standout features of the Briggs & Stratton 30253 is its robust engine. Powered by a Briggs & Stratton 800 series engine, it delivers a solid output, ensuring that you have enough energy to run essential appliances and tools. With a running wattage of 3,000 and a starting wattage of 3,500, this generator is capable of powering items such as refrigerators, lights, and power tools simultaneously, making it perfect for home backup during outages or for use on job sites.

The design of the 30253 emphasizes portability and ease of use. It features a compact and lightweight frame, allowing for easy transport and storage. The built-in rugged handle and never-flat wheels provide added mobility, enabling users to maneuver the generator effortlessly across various terrains. This makes it an ideal choice for camping trips, tailgating, or any outdoor project where power is needed.

In terms of technology, the Briggs & Stratton 30253 is equipped with a reliable low-oil shutdown feature, which automatically turns off the engine when oil levels are critically low, safeguarding the generator from potential damage. Additionally, the generator is designed with a durable steel frame and a protective roll cage, enhancing its longevity and performance in tough conditions.

Noise is a common concern with generators, but the 30253 operates at a relatively quiet level, making it more suitable for residential areas or during night use, allowing you to enjoy power without disturbing your neighbors.

Another key characteristic of the Briggs & Stratton 30253 is its user-friendly control panel. The panel includes multiple outlets, including two 120V household outlets and a 12V DC outlet, providing versatility for connecting different devices.

In summary, the Briggs & Stratton 30253 generator combines power, portability, and advanced features, making it an excellent choice for those in need of reliable electricity in various settings. Whether you're preparing for a power outage or setting up for a weekend getaway, this generator is designed to fulfill your energy needs efficiently and effectively.