SAFETY RULES

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure (even if doors or windows are open), including the generator compartment of a recreational vehicle (RV).

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

If fuel spills, wait until it evaporates before starting engine.

WHEN OPERATING EQUIPMENT

Do not tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

3

Page 3
Image 3
Briggs & Stratton 30253 manuel dutilisation When Adding or Draining Fuel, When Starting Equipment, When Operating Equipment

30253 specifications

Briggs & Stratton 30253 is a powerful and versatile portable generator designed to meet the needs of both homeowners and outdoor enthusiasts. Renowned for its reliability and efficient performance, this generator provides a dependable source of power during emergencies, outdoor events, or for recreational activities.

One of the standout features of the Briggs & Stratton 30253 is its robust engine. Powered by a Briggs & Stratton 800 series engine, it delivers a solid output, ensuring that you have enough energy to run essential appliances and tools. With a running wattage of 3,000 and a starting wattage of 3,500, this generator is capable of powering items such as refrigerators, lights, and power tools simultaneously, making it perfect for home backup during outages or for use on job sites.

The design of the 30253 emphasizes portability and ease of use. It features a compact and lightweight frame, allowing for easy transport and storage. The built-in rugged handle and never-flat wheels provide added mobility, enabling users to maneuver the generator effortlessly across various terrains. This makes it an ideal choice for camping trips, tailgating, or any outdoor project where power is needed.

In terms of technology, the Briggs & Stratton 30253 is equipped with a reliable low-oil shutdown feature, which automatically turns off the engine when oil levels are critically low, safeguarding the generator from potential damage. Additionally, the generator is designed with a durable steel frame and a protective roll cage, enhancing its longevity and performance in tough conditions.

Noise is a common concern with generators, but the 30253 operates at a relatively quiet level, making it more suitable for residential areas or during night use, allowing you to enjoy power without disturbing your neighbors.

Another key characteristic of the Briggs & Stratton 30253 is its user-friendly control panel. The panel includes multiple outlets, including two 120V household outlets and a 12V DC outlet, providing versatility for connecting different devices.

In summary, the Briggs & Stratton 30253 generator combines power, portability, and advanced features, making it an excellent choice for those in need of reliable electricity in various settings. Whether you're preparing for a power outage or setting up for a weekend getaway, this generator is designed to fulfill your energy needs efficiently and effectively.